Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
828-9702Item number
NIIN 00-828-9702
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part number
2XAM17-25-120AC60
CAGE
74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
CAGE status
H
RNCC
3
RNVC
9
Document availability code
E
RNAAC
TX
RNFC
3
RNSC
D

Characteristics

FRAGILITY FACTORMODERATELY RUGGED
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.180 AND INCHES MAXIMUM 1.200
NOMINAL THREAD SIZEINCHES 0.138
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 25.0
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.802 AND INCHES MAXIMUM 1.822
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
BUSHING LENGTHINCHES MINIMUM 0.146 AND INCHES MAXIMUM 0.166
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 2
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 120.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 3500.0
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTHINCHES MINIMUM 1.510 AND INCHES MAXIMUM 1.530
TERMINAL TYPE AND QUANTITYTAB W/SCREW 4
POLE QUANTITY2
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 40.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
FREQUENCY IN HERTZ60.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
BODY STYLE
ARC QUENCHING METHODMAGNETIC BLOWOUT

MOE rules

MOE rule
ZC01
MOE CD
ZC
Date assigned
01-APR-91
PICA
ZC
PICA LOA
81
Auth collab
ZC

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Hazardous material code
FF
Less than truckload
W
Less than carload
P
Water commodity code
658
Type of cargo code
Z
Special handling code
5
Air dimension code
A
Air commodity code
HY
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
24-OCT-1970
NIIN status code
0

Request a quote