Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
834-0272Item number
NIIN 00-834-0272
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
AM12HKMG3-15-0-2374193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H39ETX3D
AM12HKMG6-15-50C574193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETX3D

Characteristics

SWITCH TERMINAL TYPETAB, SOLDER LUG
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 250.0 AND DC 50.0
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 15.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 50.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.928 AND INCHES MAXIMUM 1.948
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.052 AND INCHES MAXIMUM 2.072
RESET METHODMANUAL
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.170 AND MAXIMUM AT 200 PCT 0.500
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDEXPLOSION RESISTANT AND FUNGUS RESISTANT AND MOISTURE RESISTANT
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
SWITCH CURRENT RATING AND TYPE IN AMPSAC 2.5 AND DC 1.0
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 2.052 AND INCHES MAXIMUM 2.072
POLE QUANTITY1
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
MATERIALCASE PLASTIC
NOMINAL THREAD SIZEINCHES 0.138
TERMINAL TYPE AND QUANTITYTHREADED STUD 2
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
ULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION MINIMUM 0.700 AND MAXIMUM 2.800
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 2000.0
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTHINCHES MINIMUM 0.130 AND INCHES MAXIMUM 0.150
BODY STYLE
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
FRAGILITY FACTORMODERATELY RUGGED
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
BOSS HEIGHTINCHES MINIMUM 0.130 AND INCHES MAXIMUM 0.150

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
ZP01ZP01-APR-91ZP81ZP
ZU01ZU01-APR-91ZU81ZU

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
14-JAN-2026
NIIN status code
0

Request a quote