Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
837-2389Item number
NIIN 00-837-2389
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-DEC-66
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
AP111-7E81541
SENSATA TECHNOLOGIES MARYLAND, INC
A516HH3D
AP112-7E81541
SENSATA TECHNOLOGIES MARYLAND, INC
A526HH3D
260-4044-05013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A39ATX1D

Characteristics

STORAGE TYPEGENERAL PURPOSE WAREHOUSE
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
RESET METHODMANUAL
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
BODY LENGTHINCHES MAXIMUM 1.562
BODY WIDTHINCHES MAXIMUM 1.937
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MAXIMUM 0.906
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDVIBRATION RESISTANT AND SHOCK RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND HERMETICALLY SEALED
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 4.500
FREQUENCY IN HERTZ400.0
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 13499-260-4044
THREAD SERIES DESIGNATORUNEF
TERMINAL TYPE AND QUANTITYWIRE HOOK 6
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.375
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.055 AND MAXIMUM AT 200 PCT 0.950
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 2.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.828
POLE QUANTITY3
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
THREAD PITCH DIAMETERSINCHES 0.3503 TO 0.3537
BODY STYLE
BUSHING LENGTHINCHES MINIMUM 0.280 AND INCHES MAXIMUM 0.380
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1

MOE rules

MOE rule
YB01
MOE CD
YB
Date assigned
01-SEP-09
PICA
YB
PICA LOA
81
Auth collab
YB

Freight

ACTY CD
HH
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
08-FEB-1980
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.