Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
906-1963Item number
NIIN 00-906-1963
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
PSM33R10ADCL10AC74193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETX3D
HE2-A3B3L10-240-1-60HZ-R10-50DC274193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETXB
5093982340
L3HARRIS TECHNOLOGIES, INC.
A32ATX3D

Characteristics

NOMINAL THREAD SIZEINCHES 0.375
BODY LENGTHINCHES MAXIMUM 1.562
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSECOND LOCATION DC 500.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONBETWEEN POLE ONE AND TWO
BODY WIDTHINCHES MAXIMUM 1.281
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.700
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSFIRST LOCATION AC 300.0
BUSHING LENGTHINCHES NOMINAL 0.375
THREAD SERIES DESIGNATORUNEF
TERMINAL TYPE AND QUANTITYWIRE HOOK 4
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSFIRST LOCATION AC 240.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
FREQUENCY IN HERTZ60.0
THREAD QUANTITY PER INCH32
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSECOND LOCATION DC 50.0
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
BODY STYLE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTFIRST LOCATION MINIMUM AT 200 PCT 0.200 AND MAXIMUM AT 200 PCT 8.000
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSECOND LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESECOND LOCATION AMPERES DC 10.0
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEFIRST LOCATION AMPERES AC 10.0

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-SEP-09YB81YB
ZU01ZU01-JUN-06ZU81ZU

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
08-FEB-1980
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-737-7812
NIIN status code
7
Effective date
01-JUL-2026
DEMIL code
A

Request a quote