Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
918-3023Item number
NIIN 00-918-3023
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-60
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
1163S50-125VDC374193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETX3D
260-2495-00013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A325TX3D

Characteristics

OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 125.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
POLE QUANTITY1
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4 AND UNTHREADED HOLE(S) 4
BODY STYLE
BODY LENGTHINCHES MINIMUM 5.240 AND INCHES MAXIMUM 5.260
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
BODY WIDTHINCHES MINIMUM 1.490 AND INCHES MAXIMUM 1.510
BOSS HEIGHTINCHES MINIMUM 0.208 AND INCHES MAXIMUM 0.228
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
ACTUATOR FUNCTIONTRIP-RESET
MATERIALCASE PLASTIC
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.190
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.180 AND MAXIMUM AT 200 PCT 0.450
FRAGILITY FACTORMODERATELY RUGGED
TERMINAL TYPE AND QUANTITYCOMPRESSION 2
ACTUATOR POSITION DESIGNATIONAT POLE ONE
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 5000.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 4.349 AND INCHES MAXIMUM 4.369
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.974 AND INCHES MAXIMUM 0.994
BODY HEIGHTINCHES MINIMUM 2.678 AND INCHES MAXIMUM 2.698
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 50.0
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 4.349 AND INCHES MAXIMUM 4.369

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZA01ZA01-APR-91ZA81ZA
ZR01ZR01-JUL-97ZR81ZR

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
5
Air dimension code
A
Air commodity code
HY
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
10-MAY-1971
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.