Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
924-9578Item number
NIIN 00-924-9578
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-JAN-66
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
10580351464
OPTOMECHANISMS CO OF AMERICA INC
H594TX1B
632238-20656232
LOCKHEED MARTIN CORPORATION DIV RMS - MITCHEL FIELD
A525TX3D
AM12MG6-30-250-4-6074193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
HC1ETXAF
AM12MG6-30-250VAC60C474193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H39ETX3D
70-868MG3-20674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H595TX3D
122-230-10177342
TE CONNECTIVITY CORPORATION
A52ETX
122-230-10179405
WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
H59ETX3B
SMC60299180063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A525TX3D
63A109B15610001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A52ATX3D

Characteristics

ACTUATOR POSITION DESIGNATIONAT POLE ONE
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 10.000
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
ACTUATOR FUNCTIONTRIP-RESET
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 30.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.611
POLE QUANTITY1
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
FREQUENCY IN HERTZ60.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 2
BOSS HEIGHTINCHES NOMINAL 0.140
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.062
FRAGILITY FACTORMODERATELY RUGGED
BODY WIDTHINCHES NOMINAL 0.750
RESET METHODMANUAL
BODY STYLE
BODY LENGTHINCHES NOMINAL 2.500
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.938

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YD01YD01-AUG-16YD81YD
YS01YS01-FEB-15YS81YS
ZC01ZC01-APR-91ZC81ZC
ZR01ZR01-APR-91ZR81ZR
ZW01ZW01-NOV-98ZW81ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
04-DEC-1973
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-852-1849
NIIN status code
7
Effective date
02-JUL-2026
DEMIL code
A

Request a quote