Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
949-1200Item number
NIIN 00-949-1200
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
13-APR-66
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
AM333MG6-32-250-16-40074193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H39ETX
AM333MG6-32-250VAC400C1674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H596TX3B
APL-111-1-41-323-M81541
SENSATA TECHNOLOGIES MARYLAND, INC
A52ETX

Characteristics

MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
RESET METHODMANUAL
ACTUATOR FUNCTIONTRIP-RESET
BODY WIDTHINCHES MAXIMUM 2.250
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.940
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.750
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.050 AND INCHES MAXIMUM 2.070
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.750
FRAGILITY FACTORMODERATELY RUGGED
BOSS HEIGHTINCHES NOMINAL 0.150
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.475
POLE QUANTITY3
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 6
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 5000.0
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
BODY STYLE
ACTUATOR POSITION DESIGNATIONAT EACH POLE
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.200 AND MAXIMUM AT 200 PCT 2.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 11.100
FREQUENCY IN HERTZ400.0
BODY LENGTHINCHES MINIMUM 2.480 AND INCHES MAXIMUM 2.500
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
THREAD PITCH DIAMETERSINCHES 0.1177 TO 0.1214
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 32.0
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
ARC QUENCHING METHODMAGNETIC BLOWOUT

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-SEP-08YB81YB
ZH01ZH01-APR-91ZH81ZH
ZW01ZW01-NOV-05ZW81ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
5
Orig stdzn dec
96
Dt stdzn dec
23-FEB-1996
NIIN status code
0

Cancelled and replaced NIINs

FSC
5925
Cancelled NIIN
5925-00-061-7368
NIIN status code
5
Effective date
02-JUL-2026
DEMIL code
A

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.