Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
952-4545Item number
NIIN 00-952-4545
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
SM333-2-230VAC400C274193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ETX3B
AP112-1-4-1-20281541
SENSATA TECHNOLOGIES MARYLAND, INC
A51ETX3D
7501200380189944
ELBITAMERICA, INC.
A525TX3D
260-3430-0013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A59ATX3D
260-3430-00013499
ROCKWELL COLLINS, INC. DBA COLLINS AEROSPACE GOVERNMENT SYSTEMS DIV COLLINS AEROSPACE - GOVERNMENT SYSTEMS
A395TX3D

Characteristics

RESET METHODMANUAL
THREAD QUANTITY PER INCH32
THREAD PITCH DIAMETERSINCHES 0.3503 TO 0.3537
BODY STYLE
BUSHING LENGTHINCHES NOMINAL 0.375
BODY LENGTHINCHES MAXIMUM 1.500
BODY WIDTHINCHES MAXIMUM 1.875
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
TERMINAL TYPE AND QUANTITYWIRE HOOK 6
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE AND MOISTURE RESISTANT AND WEATHERPROOF
FREQUENCY IN HERTZ400.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 300.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.625
FRAGILITY FACTORMODERATELY RUGGED
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 230.0
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.780
POLE QUANTITY3
ARC QUENCHING METHODMAGNETIC BLOWOUT
THREAD SERIES DESIGNATORUNEF
NOMINAL THREAD SIZEINCHES 0.375
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS MINIMUM 0.700 AND MAXIMUM 3.500
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
ACTUATOR POSITION DESIGNATIONAT POLE TWO
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 2.0
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.875
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.170 AND MAXIMUM AT 200 PCT 0.600
ACTUATOR FUNCTIONTRIP-RESET

MOE rules

MOE rule
ZR01
MOE CD
ZR
Date assigned
01-JUL-97
PICA
ZR
PICA LOA
81
Auth collab
ZR

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
08-FEB-1980
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.