Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
984-9574Item number
NIIN 00-984-9574
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-62
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
104-235-10277342
TE CONNECTIVITY CORPORATION
A32ETXD
2035B79405
WOOD ELECTRIC OPERATIONS POTTER AND BRUMFIELD DIV AMF INC
H595TX3B
BACC18J35A81205
THE BOEING COMPANY DIV DEFENSE
A525TX3D
BAC18J135A82918
THE BOEING COMPANY DIV LEGACY WICHITA
A525TX3D
1200-003-3581640
SAFRAN POWER USA, LLC
A525ZZD
BACC18J35A08903
THE BOEING COMPANY
A595TX3B

Characteristics

RESET METHODMANUAL
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 35.0 AND AMPERES DC 35.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 205.0 AND DC 30.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 3500.0 AND DC 6000.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB W/SCREW 2
POLE QUANTITY1
ULTIMATE TRIP TIME PER POLE IN SECONDSSINGLE LOCATION NOMINAL 3600.000
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.160 AND INCHES MAXIMUM 1.220
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.796 AND INCHES MAXIMUM 1.828
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 55.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
TRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.000
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
BODY STYLE
BUSHING LENGTHINCHES MINIMUM 0.220 AND INCHES MAXIMUM 0.280
BODY LENGTHINCHES MAXIMUM 2.189
BODY WIDTHINCHES MAXIMUM 0.750
NOMINAL THREAD SIZEINCHES 0.138
UNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 0.250
FREQUENCY IN HERTZ400.0
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
TRIP RELEASE METHODSINGLE LOCATION THERMAL
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZR01ZR01-APR-91ZR81ZR
ZW01ZW01-NOV-05ZW81ZW

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
3
Orig stdzn dec
TX
Dt stdzn dec
22-AUG-1965
NIIN status code
0

Request a quote