Catalog item

CIRCUIT BREAKER

5925FSC
00NCB code
993-0371Item number
NIIN 00-993-0371
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MD1503AC76374
SAFRAN ELECTRICAL & POWER USA, LLC DBA LABINAL POWER SYSYEMS USE CAGE CODE 81640 FOR CATALOGING
R595TX3B
BACC18K1503A81205
THE BOEING COMPANY DIV DEFENSE
A32ATX3D
MP1503A-C81640
SAFRAN POWER USA, LLC
A59AZZB

Characteristics

BODY LENGTHINCHES MINIMUM 1.122 AND INCHES MAXIMUM 1.152
TRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
NOMINAL THREAD SIZEINCHES 0.469
BODY WIDTHINCHES MINIMUM 0.672 AND INCHES MAXIMUM 0.702
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
ACTUATOR POSITION DESIGNATIONAT POLE ONE
BUSHING LENGTHINCHES MAXIMUM 0.250
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 0.655 AND INCHES MAXIMUM 0.685
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION THERMAL
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCK RESISTANT AND VIBRATION RESISTANT
THREAD QUANTITY PER INCH32
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 1.859
POLE QUANTITY1
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING 1
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 200.0 AND DC 28.0
SPECIAL FEATURES12 LBS. FORCE TO CLOSE BREAKER
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNS
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 4.000 AND MAXIMUM AT 200 PCT 1.800
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 5000.0 AND DC 5000.0
TERMINAL TYPE AND QUANTITYTAB W/SCREW 2
MANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 1
ACTUATOR FUNCTIONTRIP-RESET
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 2.0 AND AMPERES DC 2.0
BODY STYLE
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY

MOE rules

MOE rule
ZC01
MOE CD
ZC
Date assigned
01-APR-91
PICA
ZC
PICA LOA
81
Auth collab
ZC

Freight

ACTY CD
XX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
2
Orig stdzn dec
TX
Dt stdzn dec
07-NOV-1969
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.