CIRCUIT BREAKER

5925FSC
01NCB code
043-7346Item number
NIIN 01-043-7346
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
Y
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
29-JUN-77
Precious metals indicator
S
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
NQB-A10189946
EATON CORPORATION DBA EATON INOAC
A313TX4D
L0231716236
DLA WEAPONS SUPPORT (COLUMBUS) DBA DLA VENDOR ITEM DRAWING (VID) DIV DOCUMENT STANDARDIZATION DIVISION (VA)
A321TXD

Characteristics

BODY STYLE
BODY LENGTHINCHES NOMINAL 6.500
BODY WIDTHINCHES NOMINAL 4.125
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 5.562
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.375
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.281
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.625
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.750
BOSS HEIGHTINCHES NOMINAL 0.187
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 3.875
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
FEATURES PROVIDEDINTERCHANGEABLE TRIP RELEASE
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 5.0 AND AMPERES DC 5.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 10000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 2
ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPSALL LOCATIONS DC 600.0 TO 700.0
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
SWITCH TERMINAL TYPEWIRE LEAD
CRITICALITY CODE JUSTIFICATIONFEAT
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L02317; @FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY
MATERIALCASE PLASTIC
PRECIOUS MATERIAL AND LOCATIONSILVER CONTACTS
PRECIOUS MATERIALSILVER
TERMINAL TYPE AND QUANTITYTHREADED STUD 6

MOE rules

MOE rule
YB01
MOE CD
YB
Date assigned
01-APR-91
PICA
YB
PICA LOA
81
Auth collab
YB

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI