Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
100-0970Item number
NIIN 01-100-0970
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
28-AUG-80
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Schedule B export code
8536200040
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
JA3-Z18-674193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59ATX4B
UPGH111-1ERC2-2630-681541
SENSATA TECHNOLOGIES MARYLAND, INC
A59EZZB
13216E6205-697403
CECOM LR CENTER
A32ATX4D

Characteristics

BODY STYLE
BODY LENGTHINCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015
BODY WIDTHINCHES MINIMUM 2.245 AND INCHES MAXIMUM 2.255
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.555 AND INCHES MAXIMUM 1.565
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 1.655 AND INCHES MAXIMUM 1.665
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755
FRAGILITY FACTORMODERATELY RUGGED
BOSS HEIGHTINCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.135
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 1.835 AND INCHES MAXIMUM 1.845
POLE QUANTITY3
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 33.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 208.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 1.500 AND MAXIMUM AT 200 PCT 6.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF
SWITCH TERMINAL TYPETAB, SOLDER LUG
SWITCH CURRENT RATING AND TYPE IN AMPSAC 5.0 AND DC 5.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 125.0 AND DC 28.0
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTAB W/SCREW 6

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
WG01WG01-OCT-17WG81WG
YB01YB01-DEC-96YB81YB
YD01YD01-NOV-16YD81YD
ZH01ZH01-NOV-02ZH81ZH
VJ01VJ01-MAR-19VJ81VJ

Freight

ACTY CD
PA
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72D
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
28-AUG-1980
NIIN status code
0