Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
107-8010Item number
NIIN 01-107-8010
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 13-FEB-81
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
- Last known source of supply
- F2U
Part numbers
- Part number
- JA1-B3-12-2
- CAGE
- 74193EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
- CAGE status
- H
- RNCC
- 3
- RNVC
- 9
- Document availability code
- 4
- RNAAC
- 9Z
- RNFC
- 4
- RNSC
- D
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES NOMINAL 2.000 |
| BODY WIDTH | INCHES NOMINAL 0.750 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.560 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.660 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 1.840 |
| POLE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| THREAD QUANTITY PER INCH | 32 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 12.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 65.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION DC 1000.0 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| ULTIMATE TRIP TIME PER POLE IN SECONDS | SINGLE LOCATION MAXIMUM 50.000 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| NOMINAL THREAD SIZE | INCHES 0.138 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.650 AND MAXIMUM AT 200 PCT 8.000 AND MINIMUM AT 400 PCT 0.150 AND MAXIMUM AT 400 PCT 1.500 AND MINIMUM AT 500 PCT 0.080 AND MAXIMUM AT 500 PCT 0.800 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 2 |
MOE rules
- MOE rule
- YQ01
- MOE CD
- YQ
- Date assigned
- 01-JAN-15
- PICA
- YQ
- PICA LOA
- 81
- Auth collab
- YQ
Freight
- ACTY CD
- YQ
- NMFC
- 061700
- NMFC sub
- Z
- Uniform freight class
- 34580
- Less than truckload
- W
- Less than carload
- P
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- ELEC APPLIANCES/INSTRUMENTS NOI
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 13-FEB-1981
- NIIN status code
- 0
Request a quote