Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
114-4243Item number
NIIN 01-114-4243
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
16-JUN-81
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part number
205-11-1REC3-52F-2-303-A-M-O
CAGE
81541
SENSATA TECHNOLOGIES MARYLAND, INC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
4
RNAAC
9Z
RNFC
4
RNSC
A

Characteristics

BODY STYLE
BODY LENGTHINCHES NOMINAL 2.490
BODY WIDTHINCHES MAXIMUM 1.500
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.940
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MAXIMUM 0.750
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.060
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MAXIMUM 0.750
BOSS HEIGHTINCHES NOMINAL 0.150
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.506
POLE QUANTITY2
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 4
FEATURES PROVIDEDSLIDING BAR INTERLOCK
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES DC 30.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS DC 65.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS DC 1000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS MAXIMUM 100.000
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 2
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEMILLIMETERS 3.0
THREAD PITCH IN MILLIMETERS0.50
SWITCH LOCATION AND POSITION DESIGNATIONEXTERNAL AT POLE ONE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.620 AND MAXIMUM AT 200 PCT 15.000 AND MINIMUM AT 400 PCT 0.150 AND MAXIMUM AT 400 PCT 1.500 AND MINIMUM AT 600 PCT 0.030 AND MAXIMUM AT 600 PCT 0.500
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF AND MOISTURE RESISTANT AND SALT SPRAY PROOF
SWITCH TERMINAL TYPETAB, SOLDER LUG
SWITCH CURRENT RATING AND TYPE IN AMPSAC 10.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 250.0
THREAD TOLERANCE CLASSEXTERNAL -3
SPECIAL FEATURESBLACK HANDLE
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORISO M
TERMINAL TYPE AND QUANTITYTHREADED STUD 4

MOE rules

MOE rule
ZF01
MOE CD
ZF
Date assigned
01-APR-91
PICA
ZF
PICA LOA
81
Auth collab
ZF

Freight

ACTY CD
ZF
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Less than carload
P
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
16-JUN-1981
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.