Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
166-4051Item number
NIIN 01-166-4051
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 11-NOV-83
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
Part numbers
- Part number
- AP-6-1-52-153
- CAGE
- 81541SENSATA TECHNOLOGIES MARYLAND, INC
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- E
- RNAAC
- TX
- RNFC
- 4
- RNSC
- D
Characteristics
| BODY STYLE | |
|---|---|
| BUSHING LENGTH | INCHES MAXIMUM 0.380 |
| BODY LENGTH | INCHES MAXIMUM 1.500 |
| BODY WIDTH | INCHES MAXIMUM 0.625 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.875 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 1.605 |
| POLE QUANTITY | 1 |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING WITH PANEL SEAL 1 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| SPECIAL HANDLING FEATURE | MAGNETIC |
| THREAD QUANTITY PER INCH | 32 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 15.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 32.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION DC 1000.0 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| NOMINAL THREAD SIZE | INCHES 0.375 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.850 AND MAXIMUM AT 200 PCT 4.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
| THREAD SERIES DESIGNATOR | UNEF |
| TERMINAL TYPE AND QUANTITY | TAB W/SCREW 2 |
MOE rules
- MOE rule
- YD01
- MOE CD
- YD
- Date assigned
- 01-NOV-16
- PICA
- YD
- PICA LOA
- 81
- Auth collab
- YD
Freight
- ACTY CD
- ZE
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 11-NOV-1983
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.