Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
194-3674Item number
NIIN 01-194-3674
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
14-NOV-84
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
APGN-11-1-62-303-C-0981541
SENSATA TECHNOLOGIES MARYLAND, INC
A3249ZA
283550-1713U6441
ATLANTIC INERTIAL SYSTEMS LIMITED
A522ZKD

Characteristics

BODY STYLE
BUSHING LENGTHINCHES MINIMUM 0.480 AND INCHES MAXIMUM 0.510
BODY LENGTHINCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015
BODY WIDTHINCHES MINIMUM 1.495 AND INCHES MAXIMUM 1.525
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.515 AND INCHES MAXIMUM 1.545
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765
NONTURN DEVICE RADIUSINCHES MINIMUM 0.641 AND INCHES MAXIMUM 0.671
NONTURN DEVICE LENGTHINCHES MINIMUM 0.115 AND INCHES MAXIMUM 0.145
NONTURN DEVICE DIAMETERINCHES MINIMUM 0.151 AND INCHES MAXIMUM 0.161
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.232
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 30.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 277.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 5000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.500
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND SALT SPRAY PROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 6.000
SPECIAL FEATURESTOGGLE HANDLE WHITE WITH WHITE MARKINGS
FREQUENCY IN HERTZ50.0 OR 60.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUN
TERMINAL TYPE AND QUANTITYSCREW 4

MOE rules

MOE rule
ZK01
MOE CD
ZK
Date assigned
01-MAR-97
PICA
ZK
PICA LOA
81
Auth collab
ZK

Freight

ACTY CD
ZK

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
14-NOV-1984
NIIN status code
0

Request a quote