Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
270-0992Item number
NIIN 01-270-0992
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 29-DEC-87
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
Part numbers
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015 |
| BODY WIDTH | INCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 1.515 AND INCHES MAXIMUM 1.545 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES MINIMUM 1.645 AND INCHES MAXIMUM 1.675 |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| BOSS HEIGHT | INCHES MINIMUM 0.115 AND INCHES MAXIMUM 0.145 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 2.000 |
| POLE QUANTITY | 1 |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| SPECIAL HANDLING FEATURE | MAGNETIC |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 15.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 250.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 1000.0 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| NOMINAL THREAD SIZE | MILLIMETERS 3.0 |
| THREAD PITCH IN MILLIMETERS | 0.50 |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 10.000 AND MAXIMUM AT 200 PCT 150.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | MOISTURE RESISTANT AND SALT WATER RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| SWITCH TERMINAL TYPE | QUICK DISCONNECT, MALE |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 4.0 AND DC 2.5 |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 250.0 AND DC 30.0 |
| UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 2.200 |
| SPECIAL FEATURES | ACTUATOR BLACK WITH WHITE MARKINGS; INERTIAL DELAY INCLUDED WITH ITEM |
| FREQUENCY IN HERTZ | 50.0 OR 60.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | ISO S |
| TERMINAL TYPE AND QUANTITY | QUICK DISCONNECT, MALE 2 |
MOE rules
- MOE rule
- ZG01
- MOE CD
- ZG
- Date assigned
- 01-APR-91
- PICA
- ZG
- PICA LOA
- 81
- Auth collab
- ZG
Freight
- ACTY CD
- ZG
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 29-DEC-1987
- NIIN status code
- 0
Request a quote