Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
295-0612Item number
NIIN 01-295-0612
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
27-FEB-89
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-PRF-55629/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
MIL-C-55629/2181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A5949Z4B
M55629/21FNFN81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A2249Z4D

Characteristics

BODY STYLE
BUSHING LENGTHINCHES MINIMUM 0.464 AND INCHES MAXIMUM 0.526
BODY LENGTHINCHES MINIMUM 1.969 AND INCHES MAXIMUM 2.031
BODY WIDTHINCHES MAXIMUM 1.515
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.499 AND INCHES MAXIMUM 1.561
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.735 AND INCHES MAXIMUM 0.765
NONTURN DEVICE RADIUSINCHES MINIMUM 0.641 AND INCHES MAXIMUM 0.671
NONTURN DEVICE LENGTHINCHES MINIMUM 0.115 AND INCHES MAXIMUM 0.145
NONTURN DEVICE DIAMETERINCHES NOMINAL 0.138
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
FRAGILITY FACTORMODERATELY RUGGED
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.232
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED BUSHING WITH PANEL SEAL 1
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 1.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 240.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE TWO
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.500
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.160 AND MAXIMUM AT 200 PCT 1.600
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT
SWITCH TERMINAL TYPETAB, SOLDER LUG
SWITCH CURRENT RATING AND TYPE IN AMPSAC 10.0 AND DC 2.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 250.0 AND DC 50.0
FREQUENCY IN HERTZ60.0
MATERIALCASE PLASTIC
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-55629
THREAD SERIES DESIGNATORUN
TERMINAL TYPE AND QUANTITYTAB W/SCREW 4
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-55629 TO 21

MOE rules

MOE rule
ZC01
MOE CD
ZC
Date assigned
01-APR-91
PICA
ZC
PICA LOA
81
Auth collab
ZC

Freight

ACTY CD
ZC

Related items

Standardization

Related NSNItem standardization codeOrig stdzn decDt stdzn decNIIN status code
1TX09-MAR-20210
3TX09-MAR-20210
5925-01-358-03073TX09-MAR-20210

Request a quote