Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
296-8293Item number
NIIN 01-296-8293
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 24-MAR-89
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
Part numbers
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES MINIMUM 2.480 AND INCHES MAXIMUM 2.500 |
| BODY WIDTH | INCHES MAXIMUM 1.500 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.940 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 0.750 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES MINIMUM 2.050 AND INCHES MAXIMUM 2.070 |
| SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 0.750 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| BOSS HEIGHT | INCHES NOMINAL 0.150 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 2.475 |
| POLE QUANTITY | 2 |
| ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 4 |
| SPECIAL HANDLING FEATURE | MAGNETIC |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS MILLIAMPERES AC 500.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 250.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 5000.0 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 2 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| NOMINAL THREAD SIZE | MILLIMETERS 3.0 |
| THREAD PITCH IN MILLIMETERS | 0.50 |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 22.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT AND FUNGUS RESISTANT |
| SWITCH TERMINAL TYPE | QUICK DISCONNECT, MALE |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 10.0 AND DC 3.0 |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 250.0 AND DC 50.0 |
| UNPACKAGED UNIT WEIGHT | OUNCES NOMINAL 7.400 |
| FREQUENCY IN HERTZ | 400.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | ISO S |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 4 |
Freight
- ACTY CD
- ZF
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 24-MAR-1989
- NIIN status code
- 6
History
Identification changes
- Item name code
- 00136
- Item standardization code
- 5
- DEMIL code
- A
- Criticality code
- X
- Precious metals indicator
- U
- Cancelled date
- 10-JUN-2026
- NIIN status code
- 6
Past part numbers
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.