Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
297-9393Item number
NIIN 01-297-9393
Request a quote
Unit price
$80.59
Unit of issue
EA
Source of supply
G69
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
N
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
08-APR-89
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective date
01-OCT-2025
Major organizational entity
GE
Acquisition advice code
G
Source of supply
G69
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$80.59
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
AM2A8A8-2074193
EATON CORP HEINEMANN PRODUCTS COMMERCIAL CONTROLS DIV
H59548B
AM2A8A8-2008125
U S DEPT OF TRANSPORTATION FEDERAL AVIATION ADMINISTRATION
A325ZZ

Characteristics

BODY STYLE
BODY LENGTHINCHES MINIMUM 2.490 AND INCHES MAXIMUM 2.510
BODY WIDTHINCHES MINIMUM 2.220 AND INCHES MAXIMUM 2.280
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.928 AND INCHES MAXIMUM 1.948
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.052 AND INCHES MAXIMUM 2.072
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 0.740 AND INCHES MAXIMUM 0.760
FRAGILITY FACTORMODERATELY RUGGED
END ITEM IDENTIFICATIONREMOTE SYSTEM MONITOR (RSM)
BOSS HEIGHTINCHES MINIMUM 0.130 AND INCHES MAXIMUM 0.140
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MINIMUM 2.549 AND INCHES MAXIMUM 2.673
POLE QUANTITY2
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
FEATURES PROVIDEDHIGH INRUSH PROTECTION
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 20.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 250.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT EACH POLE
EXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
NOMINAL THREAD SIZEINCHES 0.138
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF
FREQUENCY IN HERTZ60.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 6

MOE rules

MOE rule
B481
MOE CD
GE
AMC
1
AMSC
H
Date assigned
01-FEB-02
PICA
48
PICA LOA
02
Auth collab
48

Freight

ACTY CD
48

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
08-APR-1989
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.