Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
307-0690Item number
NIIN 01-307-0690
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
07-SEP-89
Precious metals indicator
U
Hazardous material indicator
P
Schedule B export code
8536200040

Part numbers

Part number
APG-6-1REC3-42F-152-A
CAGE
81541
SENSATA TECHNOLOGIES MARYLAND, INC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
E
RNAAC
TX
RNFC
4
RNSC
D

Characteristics

THREAD PITCH DIAMETERSMILLIMETERS 2.99 TO 3.08
BODY STYLE
BODY LENGTHINCHES NOMINAL 2.000
BODY WIDTHINCHES NOMINAL 0.750
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.530
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.660
SWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
FRAGILITY FACTORMODERATELY RUGGED
BOSS HEIGHTINCHES NOMINAL 0.130
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.000
POLE QUANTITY1
ARC QUENCHING METHODMAGNETIC BLOWOUT
MOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
SPECIAL HANDLING FEATUREMAGNETIC
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 1.5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 240.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 2100.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT115.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
ACTUATOR POSITION DESIGNATIONAT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
NOMINAL THREAD SIZEMILLIMETERS 3.5
SWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 2.200 AND MAXIMUM AT 200 PCT 25.000
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDHERMETICALLY SEALED AND SHOCK RESISTANT AND VIBRATION RESISTANT
SWITCH TERMINAL TYPEQUICK DISCONNECT, MALE
SWITCH CURRENT RATING AND TYPE IN AMPSAC 10.0 AND DC 5.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 250.0 AND DC 30.0
UNPACKAGED UNIT WEIGHTOUNCES NOMINAL 2.200
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORISO M
TERMINAL TYPE AND QUANTITYTAB W/SCREW 2

MOE rules

MOE rule
ZC01
MOE CD
ZC
Date assigned
01-APR-91
PICA
ZC
PICA LOA
81
Auth collab
ZC

Freight

ACTY CD
ZC

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
07-SEP-1989
NIIN status code
0

Request a quote