Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
330-7615Item number
NIIN 01-330-7615
Request a quote
Unit price
$1,622.00
Unit of issue
EA
Source of supply
ZNC
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
08-DEC-90
Precious metals indicator
A
Hazardous material indicator
P
Schedule B export code
8536200040

Management

Effective date
01-JAN-2012
Major organizational entity
GP
Acquisition advice code
Z
Source of supply
ZNC
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$1,622.00
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Recoverability code
C
Management control
S-09---
Net price
$0.00
USC
C

Part numbers

Part number
315C574G29
CAGE
89946
EATON CORPORATION DBA EATON INOAC
CAGE status
A
RNCC
3
RNVC
2
Document availability code
3
RNAAC
XF

Characteristics

BODY STYLE
BODY LENGTHINCHES NOMINAL 13.000
BODY WIDTHINCHES NOMINAL 8.250
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 9.875
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 6.000
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.312
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 9.875
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 3.000
END ITEM IDENTIFICATIONUSED ON POWER SUPPLY SYSTEM ONBOARD 378 FT WHEC COAST GUARD VESSELS
BOSS HEIGHTINCHES NOMINAL 0.375
MOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 9.093
POLE QUANTITY3
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 160.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 500.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 20000.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
TRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
TERMINAL TYPE AND QUANTITYCOMPRESSION 6

MOE rules

MOE rule
C056
MOE CD
GP
AMC
1
AMSC
G
Date assigned
01-JUN-10
PICA
XG
PICA LOA
26
Auth collab
XG
Fmr MOE rl
C165

Service data

Coast Guard

IAC
S
SNC
0
SMCC
9

Freight

ACTY CD
XF

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
08-DEC-1990
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.