Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
425-5902Item number
NIIN 01-425-5902
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 23-FEB-96
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- ESD/EMI code
- A
- Schedule B export code
- 8536200040
Part numbers
- Part number
- APL11-1REC4-52-753
- CAGE
- 81541SENSATA TECHNOLOGIES MARYLAND, INC
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- 4
- RNAAC
- 9Z
- RNSC
- A
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES NOMINAL 2.490 |
| BODY WIDTH | INCHES MAXIMUM 1.515 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 1.940 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 0.667 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.060 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 0.750 |
| BOSS HEIGHT | INCHES NOMINAL 0.150 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 2.475 |
| POLE QUANTITY | 2 |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 4 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES DC 75.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS DC 50.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 2000.0 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 2 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| AUXILIARY SWITCH FUNCTION AND QUANTITY | ALARM 1 |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| NOMINAL THREAD SIZE | INCHES 0.250 |
| SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 125 PCT 2.500 AND MAXIMUM AT 125 PCT 100.000 |
| INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND MOISTURE RESISTANT AND SHOCKPROOF AND VIBRATIONPROOF |
| SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
| SWITCH CURRENT RATING AND TYPE IN AMPS | AC 5.0 |
| SWITCH VOLTAGE RATING AND TYPE IN VOLTS | AC 20.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | UNF |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 4 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YB01 | YB | 01-JUL-01 | YB | 81 | YB |
| ZT01 | ZT | 01-FEB-96 | ZT | 81 | ZT |
Freight
- ACTY CD
- CL
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 23-FEB-1996
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.