Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
432-5174Item number
NIIN 01-432-5174
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 07-JUN-96
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- ESD/EMI code
- A
- Schedule B export code
- 8536200040
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| 4200-003-25 | 76374 SAFRAN ELECTRICAL & POWER USA, LLC DBA LABINAL POWER SYSYEMS USE CAGE CODE 81640 FOR CATALOGING | R | 5 | 9 | 6 | 9Z | 4 | B |
| MIL-C-5809 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 4 | 9Z | 4 | B |
| MS26574-25L | 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 4 | 9Z | 4 | B |
| 4200-003-25 | A0126 LEONARDO SPA HELICOPTERS DIVISION - PRODUCTION SITE | A | 5 | 2 | 5 | ZR | 4 | A |
| SAE-AS58091 | 0U583 SAE INTERNATIONAL DBA SAE INTERNATIONAL | A | 3 | 1 | E | ZZ | ||
| MS26574-25L | 0U583 SAE INTERNATIONAL DBA SAE INTERNATIONAL | A | 3 | 2 | E | ZZ |
Characteristics
| BODY STYLE | |
|---|---|
| BUSHING LENGTH | INCHES NOMINAL 0.250 |
| BODY LENGTH | INCHES MAXIMUM 0.780 |
| BODY WIDTH | INCHES NOMINAL 0.593 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES NOMINAL 0.593 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES NOMINAL 1.525 |
| POLE QUANTITY | 4 |
| MOUNTING FACILITY TYPE AND QUANTITY | TERMINAL 2 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES DC 20.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 115.0 AND DC 28.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 2000.0 AND DC 2000.0 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERVOLTAGE |
| TRIP RELEASE METHOD | ALL LOCATIONS THERMAL |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 130.0 |
| RESET METHOD | MANUAL |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MAXIMUM AT 130 PCT 3600.000 |
| TRIP RELEASE AMBIENT TEMP RATING | ALL LOCATIONS CELSIUS NOMINAL 25.0 |
| TERMINAL TYPE AND QUANTITY | SCREW 2 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| WG01 | WG | 01-OCT-17 | WG | 81 | WG |
| YA01 | YA | 01-JUL-01 | YA | 81 | YA |
| YW01 | YW | 01-AUG-07 | YW | 81 | YW |
| ZB01 | ZB | 01-JAN-07 | ZB | 81 | ZB |
| ZE01 | ZE | 01-APR-10 | ZE | 81 | ZE |
| ZD01 | ZD | 01-JAN-11 | ZD | 81 | ZD |
| ZP01 | ZP | 01-MAY-18 | ZP | 81 | ZP |
| ZR01 | ZR | 01-JUN-96 | ZR | 81 | ZR |
Freight
- ACTY CD
- EI
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 07-JUN-1996
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.