Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
497-0343Item number
NIIN 01-497-0343
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 07-MAY-02
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- Schedule B export code
- 8536200040
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| M55629/1-393 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 2 | 2 | E | 9Z | 4 | D |
| MIL-PRF-55629/1 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 4 | 1 | E | ZZ |
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | INCHES MAXIMUM 2.530 |
| BODY WIDTH | INCHES MINIMUM 0.730 AND INCHES MAXIMUM 0.780 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 1.600 AND INCHES MAXIMUM 1.960 |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES MINIMUM 2.046 AND INCHES MAXIMUM 2.078 |
| BOSS HEIGHT | INCHES NOMINAL 0.140 |
| MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 2.553 |
| POLE QUANTITY | 1 |
| MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| SPECIAL HANDLING FEATURE | MAGNETIC |
| THREAD QUANTITY PER INCH | 28 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES DC 25.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 50.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION DC 2000.0 |
| CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC |
| TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| NOMINAL THREAD SIZE | INCHES 0.132 |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 2.500 AND MAXIMUM AT 200 PCT 20.000 |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | CIRCUIT BREAKER |
| THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | THREADED STUD 2 |
MOE rules
- MOE rule
- ZF01
- MOE CD
- ZF
- Date assigned
- 01-MAY-02
- PICA
- ZF
- PICA LOA
- 81
- Auth collab
- ZF
Freight
- ACTY CD
- 85
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 07-MAY-2002
- NIIN status code
- 0
Request a quote