Catalog item
Request a quoteCIRCUIT BREAKER
5925FSC
01NCB code
591-6151Item number
NIIN 01-591-6151
- DEMIL code
- A
Identification
- Item name code
- 00136
- PINC
- 0000136
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 02-FEB-11
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- ESD/EMI code
- A
- Schedule B export code
- 8536200040
Part numbers
- Part number
- FAZ-D16/3-NA
- CAGE
- 76526MOELLER INSTRUMENT COMPANY, INC. DBA MOELLER INSTRUMENT CO
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- E
- RNAAC
- 9Z
- RNFC
- 4
- RNSC
- A
Characteristics
| BODY STYLE | |
|---|---|
| BODY LENGTH | MILLIMETERS NOMINAL 105.0 |
| BODY WIDTH | MILLIMETERS NOMINAL 53.1 |
| BODY HEIGHT | MILLIMETERS NOMINAL 44.0 |
| CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | MILLIMETERS NOMINAL 17.7 |
| END ITEM IDENTIFICATION | AIRCRAFT C295 |
| BOSS HEIGHT | MILLIMETERS NOMINAL 16.0 |
| POLE QUANTITY | 3 |
| MOUNTING FACILITY TYPE AND QUANTITY | DIN RAIL 1 |
| MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 16.0 AND AMPERES DC 16.0 |
| OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 277.0 AND AC 480.0 AND DC 96.0 |
| MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 10000.0 AND DC 10000.0 |
| CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| TRIP RELEASE METHOD | ALL LOCATIONS MAGNETIC |
| TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS INSTANTANEOUS AND TIME DELAY |
| ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 1000.0 |
| RESET METHOD | MANUAL |
| MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 3 |
| ACTUATOR FUNCTION | TRIP-RESET |
| ACTUATOR POSITION DESIGNATION | AT POLE ONE AND AT POLE TWO AND AT POLE THREE |
| EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
| INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS RELAY TRIP |
| TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS MINIMUM AT 200 PCT 20.000 AND MAXIMUM AT 200 PCT 90.000 |
| PART NAME ASSIGNED BY CONTROLLING AGENCY | FAZ NA BRANCH CIRCUIT BREAKER TYPE D FOR HIGHLY INDUCTIVE LOAD |
| SPECIAL FEATURES | SUITABLE FOR APPLICATIONS WHERE HIGH LEVELS OF INRUSH CURRENT ARE EXPECTED; PREVENTS NUISANCE TRIPPING IN HIGH INDUCTIVE APPS |
| FREQUENCY IN HERTZ | 50.0 OR 60.0 |
| MATERIAL | CASE PLASTIC |
| TERMINAL TYPE AND QUANTITY | SCREW 6 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YB01 | YB | 01-FEB-11 | YB | 81 | YB |
| ZK01 | ZK | 01-MAY-21 | ZK | 81 | ZK |
Freight
- ACTY CD
- EA
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 02-FEB-2011
- NIIN status code
- 0
Request a quote