Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
592-2356Item number
NIIN 01-592-2356
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
28-FEB-11
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
8536200040

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-PRF-83383/0181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59E9Z4B
M83383/01-0281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22E9Z4D
MIL-PRF-83383/181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ

Characteristics

BODY STYLE
OVERALL LENGTHINCHES MAXIMUM 2.250
OVERALL HEIGHTINCHES MAXIMUM 4.260
OVERALL WIDTHINCHES MAXIMUM 1.256
UNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.172
POLE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 2
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 7.5 AND AMPERES DC 7.5
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 115.0 AND DC 28.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 3600.0 AND DC 3600.0
CIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
TRIP RELEASE METHODSINGLE LOCATION THERMAL
TRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT1000.0
RESET METHODAUTOMATIC
INTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 11.000 AND MAXIMUM AT 200 PCT 40.000
TRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS MINIMUM -54.0 AND CELSIUS MAXIMUM 71.0
FREQUENCY IN HERTZ400.0
MATERIALCASE PLASTIC
TERMINAL TYPE AND QUANTITYTHREADED STUD 2

MOE rules

MOE rule
ZK01
MOE CD
ZK
Date assigned
01-FEB-11
PICA
ZK
PICA LOA
81
Auth collab
ZK

Freight

ACTY CD
X2

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
28-FEB-2011
NIIN status code
0

Request a quote