Catalog item

CIRCUIT BREAKER

5925FSC
01NCB code
699-5647Item number
NIIN 01-699-5647
Request a quote
DEMIL code
A

Identification

Item name code
00136
PINC
0000136
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
09-FEB-22
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
ESD/EMI code
A
Schedule B export code
8536200040

Part numbers

Part number
IUG2-41445-30
CAGE
82647
SENSATA TECHNOLOGIES, INC. DIV SENSATA ATTLEBORO
CAGE status
A
RNCC
3
RNVC
2
Document availability code
3
RNAAC
9Z
RNFC
4
RNSC
A

Characteristics

BODY STYLE
OVERALL LENGTHMILLIMETERS NOMINAL 50.80
OVERALL HEIGHTMILLIMETERS MAXIMUM 52.705
OVERALL WIDTHMILLIMETERS NOMINAL 19.05
BODY LENGTHMILLIMETERS NOMINAL 50.8
BODY WIDTHMILLIMETERS NOMINAL 19.05
BODY HEIGHTMILLIMETERS NOMINAL 42.85
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHMILLIMETERS NOMINAL 38.862
UNTHREADED MOUNTING HOLE DIAMETERMILLIMETERS NOMINAL 3.96
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHMILLIMETERS NOMINAL 42.164
MOUNTING SURFACE TO TERMINAL END DISTANCEMILLIMETERS MAXIMUM 52.705
POLE QUANTITY1
MOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 2
THREAD QUANTITY PER INCH32
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 30.0 AND AMPERES DC 30.0
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 230.0 AND DC 80.0
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 30.0 AND DC 30.0
CIRCUIT PROTECTION TYPEALL LOCATIONS OVERVOLTAGE
TRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
TRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
ULTIMATE TRIP TIME PER POLE IN SECONDSALL LOCATIONS NOMINAL 52.0
RESET METHODMANUAL
MAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
MANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
ACTUATOR FUNCTIONTRIP-RESET
INTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS DUAL COIL
NOMINAL THREAD SIZEINCHES 0.1380
THREAD PITCH IN MILLIMETERS0.7938
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS NOMINAL AT 100 PCT 52.0
TRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS MINIMUM -40.0 AND CELSIUS MAXIMUM 85.0
SWITCH TERMINAL TYPETAB W/SCREW
SWITCH CURRENT RATING AND TYPE IN AMPSAC 30.0 AND DC 30.0
SWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 230.0 AND DC 80.0
UNPACKAGED UNIT WEIGHTGRAMS NOMINAL 62.4
PART NAME ASSIGNED BY CONTROLLING AGENCYIUG HYDRAULIC MAGNETIC CIRCUIT PROTECTOR
SPECIAL FEATURESTERMINAL SCREW 8-32. BLUE TOGGLE. LONG DELAY. 4 TERMINALS WITH TRIP COIL. ONE POLE.
FREQUENCY IN HERTZ60.0
MATERIALCASE PLASTIC
THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYSCREW 4

MOE rules

MOE rule
YD01
MOE CD
YD
Date assigned
01-FEB-22
PICA
YD
PICA LOA
81
Auth collab
YD

Freight

ACTY CD
YD

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
09-FEB-2022
NIIN status code
0

Request a quote