Catalog item
Request a quoteTERMINAL BOARD
5940FSC
00NCB code
178-0163Item number
NIIN 00-178-0163
- DEMIL code
- A
Identification
- Item name code
- 00404
- PINC
- 0000404
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8536908085
- Last known source of supply
- S9G
Part numbers
Characteristics
| BOARD OVERALL HEIGHT | INCHES 1.375 |
|---|---|
| BOARD OVERALL WIDTH | INCHES 1.720 |
| BOARD OVERALL LENGTH | INCHES 9.125 |
| MOUNTING HOLE DIAMETER | INCHES 0.172 |
| DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | INCHES 0.875 |
| DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | INCHES 0.250 |
| NONFEEDTHRU TERMINAL QUANTITY | SINGLE 12 |
| TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
| TERMINAL DESIGN | LINKED NONFEEDTHRU |
| SPECIAL FEATURES | TERMINAL BOARD COVER AND MARKER STRIP |
| MATERIAL | BOARD PLASTIC |
| MATERIAL | TERMINALS COPPER ALLOY |
| BOARD HEIGHT EXCLUDING TERMINALS | INCHES 1.375 |
| MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 2 |
| TERMINAL CONNECTING LINK QUANTITY | SINGLE 12 |
| NONFEEDTHRU TERMINAL TYPE | SINGLE 857 |
| TERMINAL CONNECTING LINK TYPE | SINGLE 1 |
| BOARD CONSTRUCTION | HOLLOW CONSTRUCTION WITHOUT INSULATED STRIP |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 8.625 |
| SURFACE TREATMENT | TERMINALS CADMIUM |
| BODY STYLE | |
| TERMINAL ROW QUANTITY | 2 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| YB01 | YB | 01-APR-91 | YB | 81 | YB |
| ZW01 | ZW | 01-NOV-98 | ZW | 81 | ZW |
Freight
- ACTY CD
- XX
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- CX
- Dt stdzn dec
- 15-DEC-1974
- NIIN status code
- 0
Request a quote