Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
074-2662Item number
NIIN 01-074-2662
Request a quote
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
29-MAR-79
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536490075
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
KL-D4A-00258657
LEACH INTERNATIONAL CORP DIV LEACH INTERNATIONAL CORPORATION
AC16TXD
MIL-PRF-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A414ZZ
MIL-R-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A593TX4B
MS27745-296906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX4D
EL410-200299699
DRI RELAYS INC. DBA DRI RELAYS INC
AC16TX4D

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.718
OVERALL HEIGHTINCHES NOMINAL 1.310
OVERALL WIDTHINCHES MAXIMUM 1.025
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.150
ENVIRONMENTAL PROTECTIONHERMETIC
WINDING QUANTITY2
COIL QUANTITY2
DUTY TYPECONTINUOUS
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY SLOTTED HOLE 3
FEATURES PROVIDEDLATCHING CONTACTS AND POLARIZED
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 4
NOMINAL OPERATING CURRENT RATING AND TYPEALL WINDINGS MILLIAMPERES DC 75.0
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.015
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES NOMINAL 1.421
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPALL WINDINGS VOLTS DC 25 DEG CELSIUS 28.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106
TERMINAL TYPE AND QUANTITYALL FUNCTIONS PIN 16
SPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S27745

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZS01ZS01-APR-91ZS81ZS
ZT01ZT01-APR-91ZT81ZT

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
21-JAN-1999
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.