Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
075-3886Item number
NIIN 01-075-3886
Request a quote
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
20-APR-79
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8536490075
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
KA-S2F-00358657
LEACH INTERNATIONAL CORP DIV LEACH INTERNATIONAL CORPORATION
AC16TXD
MIL-R-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59ETX4B
MIL-PRF-610681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A414ZZ
MS27400-1196906
MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22ETX4D
E410-122199699
DRI RELAYS INC. DBA DRI RELAYS INC
AC16TX4D
X22-306-66A181N
BAE SYSTEMS BOFORS AB
A5249Z4D
10132626A486G
NIMIKKEISTOKESKUS NCB FINLAND
A699WF4B
X22-306-66S3715
BOFORS AB
R5949Z4B

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.718
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.625
OVERALL HEIGHTINCHES MAXIMUM 1.420
OVERALL WIDTHINCHES MAXIMUM 1.025
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.150
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
FREQUENCY IN HERTZNOMINAL 400.0
WINDING QUANTITY1
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY1
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY SLOTTED HOLE 3
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
FEATURES PROVIDEDPOLARIZED
CUBIC MEASURECUBIC INCHES 2.500
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 4
TIME DELAYFIXED RELEASE TIME SECONDS MAXIMUM 0.05
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.02
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES NOMINAL 1.446
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPSINGLE WINDING VOLTS AC 25 DEG CELSIUS 115.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES AC 8.0 AND AMPERES DC 8.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 4.0 AND AMPERES DC 4.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106
TERMINAL TYPE AND QUANTITYALL FUNCTIONS WIRE HOOK 14
SPECIFICATION/STANDARD DATAGOVERNMENT STANDARD 96906--S27400

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
WF01WF01-APR-11WF81WF
YB01YB01-APR-91YB81YB
YD01YD01-AUG-17YD81YD
YJ01YJ01-APR-91YJ81YJ
YW01YW01-AUG-97YW81YW
ZF01ZF01-MAR-96ZF81ZF
ZG01ZG01-APR-91ZG81ZG
ZK01ZK01-APR-91ZK81ZK
ZT01ZT01-APR-91ZT81ZT
ZR01ZR01-APR-91ZR81ZR
ZU01ZU01-JUL-05ZU81ZU
ZW01ZW01-NOV-98ZW81ZW

Freight

ACTY CD
TX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
01-DEC-1988
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.