Catalog item
Request a quoteRELAY,ELECTROMAGNETIC
5945FSC
01NCB code
080-0765Item number
NIIN 01-080-0765
- DEMIL code
- A
Identification
- Item name code
- 32512
- PINC
- 0032512
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 19-JUL-79
- Precious metals indicator
- U
- Hazardous material indicator
- N
- Schedule B export code
- 8536490075
Part numbers
- Part number
- 7012PDB
- CAGE
- 89020TE CONNECTIVITY CORPORATION
- CAGE status
- A
- RNCC
- 3
- RNVC
- 2
- Document availability code
- E
- RNAAC
- TX
Characteristics
| THREAD CLASS | 2B |
|---|---|
| THREAD DIRECTION | SECOND MOUNTING FACILITY RIGHT-HAND |
| OVERALL LENGTH | INCHES MAXIMUM 3.250 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | FIRST MOUNTING FACILITY INCHES NOMINAL 2.880 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SECOND MOUNTING FACILITY INCHES NOMINAL 1.750 |
| OVERALL HEIGHT | INCHES MAXIMUM 4.520 |
| OVERALL WIDTH | INCHES MAXIMUM 3.090 |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| UNTHREADED MOUNTING HOLE DIAMETER | FIRST MOUNTING FACILITY INCHES NOMINAL 0.199 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | SECOND MOUNTING FACILITY INCHES NOMINAL 0.500 |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | FIRST MOUNTING FACILITY INCHES MINIMUM 0.750 AND INCHES MAXIMUM 1.500 |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| WINDING QUANTITY | 1 |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| COIL QUANTITY | 1 |
| DUTY TYPE | CONTINUOUS |
| ARC QUENCHING METHOD | AIR |
| MOUNTING FACILITY TYPE AND QUANTITY | FIRST MOUNTING FACILITY UNTHREADED HOLE(S) 6 |
| MOUNTING FACILITY TYPE AND QUANTITY | SECOND MOUNTING FACILITY THREADED HOLE(S) 4 |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CUBIC MEASURE | CUBIC INCHES 45.392 |
| THREAD QUANTITY PER INCH | 32 |
| NOMINAL THREAD SIZE | SECOND MOUNTING FACILITY INCHES 0.164 |
| MOUNTING FACILITY PATTERN | SECOND MOUNTING FACILITY RECTANGULAR |
| MOUNTING FACILITY PATTERN | FIRST MOUNTING FACILITY RECTANGULAR |
| NONPILE-UP MAIN CONTACT ARRANGEMENT | POLE, DOUBLE THROW, ONE POSITION MOMENTARY 2 |
| TIME DELAY | ADJUSTABLE OPERATE TIME SECONDS MINIMUM 5.00 AND SECONDS MAXIMUM 50.00 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | SINGLE WINDING VOLTS DC 25 DEG CELSIUS 125.0 |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | RESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 15.0 |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | AC 240.0 AND DC 30.0 |
| ENERGIZING ELEMENT POWER RATING | WATTS 8.0 |
| MATERIAL | CASE PLASTIC |
| THREAD SERIES DESIGNATOR | SECOND MOUNTING FACILITY UNIFIED NATIONAL COARSE (UNC) |
| TERMINAL TYPE AND QUANTITY | ALL FUNCTIONS SCREW 8 |
MOE rules
- MOE rule
- ZF01
- MOE CD
- ZF
- Date assigned
- 01-APR-91
- PICA
- ZF
- PICA LOA
- 81
- Auth collab
- ZF
Freight
- ACTY CD
- ZF
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 19-JUL-1979
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.