Catalog item

RELAY,ELECTROMAGNETIC

5945FSC
01NCB code
274-6408Item number
NIIN 01-274-6408
Request a quote
DEMIL code
A

Identification

Item name code
32512
PINC
0032512
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
11-MAR-88
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8536490075
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAAC
MIL-R-6106/5181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A413TX
M6106/51-00181349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A223TX

Characteristics

OVERALL LENGTHINCHES MAXIMUM 1.718
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.625
OVERALL HEIGHTINCHES MAXIMUM 1.320
OVERALL WIDTHINCHES MAXIMUM 1.025
MOUNTING SLOT WIDTHSINGLE MOUNTING FACILITY INCHES NOMINAL 0.150
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
WINDING QUANTITY2
PURPOSE FOR WHICH DESIGNEDGENERAL
COIL QUANTITY2
WINDING DC RESISTANCE RATINGALL WINDINGS OHMS MINIMUM 405.0
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
MOUNTING FACILITY TYPE AND QUANTITYSINGLE MOUNTING FACILITY SLOTTED HOLE 3
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
FEATURES PROVIDEDLATCHING CONTACTS
CUBIC MEASURECUBIC INCHES 2.324
MOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY TRIANGLE
NONPILE-UP MAIN CONTACT ARRANGEMENTPOLE, DOUBLE THROW, ONE POSITION MOMENTARY 4
TIME DELAYFIXED OPERATE TIME SECONDS MAXIMUM 0.015
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLESINGLE MOUNTING FACILITY INCHES NOMINAL 1.446
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMPALL WINDINGS VOLTS DC 25 DEG CELSIUS 28.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEINDUCTIVE LOAD AMPERES AC 8.0 AND AMPERES DC 8.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGEMOTOR LOAD AMPERES AC 4.0 AND AMPERES DC 4.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGELAMP LOAD AMPERES AC 2.0 AND AMPERES DC 2.0
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGERESISTIVE LOAD AMPERES AC 10.0 AND AMPERES DC 10.0
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTSAC 115.0 AND DC 28.0
TEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-6106
TERMINAL TYPE AND QUANTITYALL FUNCTIONS WIRE HOOK 16
SPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-R-6106 TO 51

MOE rules

MOE rule
ZW01
MOE CD
ZW
Date assigned
01-NOV-98
PICA
ZW
PICA LOA
81
Auth collab
ZW

Freight

ACTY CD
TX

Related items

Standardization

Item standardization code
E
Orig stdzn dec
TX
Dt stdzn dec
15-MAY-1997
NIIN status code
0

Request a quote