Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
198-8862Item number
NIIN 00-198-8862
Request a quote
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Last known source of supply
S9E

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSCSADC
52C22626916
NORTHROP GRUMMAN SYSTEMS CORPORATION DBA NORTHROP GRUMMAN SYSTEMS CORP DIV MULTIPLE
A325TX3D
70-3-24C4W146
SMART MACHINES, INC. DBA BARKER AND WILLIAMSON
AC15ZZ3D9F
SCD3431080063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A521TX3D
SCC3431080063
US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR
A595TX3B
30255899993
DEPARTMENT OF THE NAVY
H595TX3B
70-3-24C05690
BARKER & WILLIAMSON
R595TX3B

Characteristics

WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 6.30
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.438
MOUNTING FACILITY QUANTITY4
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 105.00 AND AC VOLTS NOMINAL 115.00 AND AC VOLTS NOMINAL 125.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 460.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 760.00
BODY LENGTHINCHES NOMINAL 4.500
BODY WIDTHINCHES NOMINAL 3.375
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.500
TERMINAL TYPE AND QUANTITYSTANDOFF INSULATOR 12
THREAD QUANTITY PER INCH20
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.250
RELIABILITY INDICATORNOT ESTABLISHED
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 100.0
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO INCLOSURE
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC MAXIMUM 1.0
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 60.0
BODY HEIGHTINCHES NOMINAL 5.250
INCLOSURE TYPEHERMETICALLY SEALED
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
MOUNTING METHODSINGLE GROUP THREADED STUD(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 3

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-98ZW81ZW

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
21-MAR-1968
NIIN status code
0

Request a quote