Catalog item

TRANSFORMER,POWER

5950FSC
00NCB code
686-6955Item number
NIIN 00-686-6955
Request a quote
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
01-JAN-63
Precious metals indicator
U
Hazardous material indicator
P
Last known source of supply
S9E

Part numbers

Part number
L285381-1
CAGE
06845
RAYTHEON COMPANY DBA RAYTHEON CO
CAGE status
A
RNCC
3
RNVC
2
Document availability code
5
RNAAC
TX
RNFC
1
RNSC
D

Characteristics

MOUNTING METHODSINGLE GROUP THREADED STUD(S)
RELIABILITY INDICATORNOT ESTABLISHED
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.240
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND PRIMARY AC VOLTS NOMINAL 115.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 5.00
THREAD SERIES DESIGNATORSINGLE GROUP UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYTHREADED STUD 7
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHSINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.240
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 2 AND SECONDARY 1
THREAD QUANTITY PER INCH32
NOMINAL THREAD SIZESINGLE GROUP INCHES 0.138
WINDING SHIELDING METHODSINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL
BODY LENGTHINCHES NOMINAL 3.970
BODY WIDTHINCHES NOMINAL 4.660
BODY HEIGHTINCHES NOMINAL 4.930
INCLOSURE TYPEHERMETICALLY SEALED
MOUNTING FACILITY QUANTITY4
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST PRIMARY AC VOLTS NOMINAL 3.50
WINDING OPERATING CURRENTSINGLE COMPONENT SINGLE SECONDARY AMPERES AC MAXIMUM 5.4
FREQUENCY RATINGSINGLE COMPONENT HERTZ MINIMUM 50.0 AND HERTZ MAXIMUM 60.0

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-05ZW81ZW

Freight

ACTY CD
XX
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Less than carload
P
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Related items

Standardization

Item standardization code
6
Orig stdzn dec
TX
Dt stdzn dec
07-JAN-1979
NIIN status code
0

Request a quote