Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
00NCB code
937-9531Item number
NIIN 00-937-9531
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 15-FEB-67
- Precious metals indicator
- U
- Hazardous material indicator
- P
- Last known source of supply
- S9E
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNFC | RNSC |
|---|---|---|---|---|---|---|---|---|
| C8233 | 72149 ELECTRONIC TRANSFORMER CORP DIV ELECTRONIC TRANSFORMER CORPORATION | A | 5 | 2 | 5 | TX | ||
| SM-C-540721 | 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR | A | 3 | 2 | A | TX | 1 | D |
| SM-D-686837 | 80063 US ARMY COMMUNICATIONS & ELECTRONICS MATERIEL READINESS COMMAND LOGISTICS ENGINEERING DIR | A | 5 | 2 | A | TX | 1 | D |
| CT101875A | 98330 OECO, LLC | A | 5 | 2 | 5 | ZZ | ||
| CT101875 | 98330 OECO, LLC | A | 5 | 9 | 4 | CL | 3 | D |
Characteristics
| MAXIMUM OPERATING TEMP | CELSIUS 85.0 |
|---|---|
| MOUNTING BOLT CIRCLE DIAMETER | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 1.688 |
| TERMINAL TYPE AND QUANTITY | PIN 19 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES AC MAXIMUM 50.0 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 5.30 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FOURTH SECONDARY AC VOLTS MINIMUM 212.10 AND AC VOLTS MAXIMUM 619.17 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 9.19 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY DC VOLTS MAXIMUM 4.80 |
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING FACILITY QUANTITY | 3 |
| MOUNTING METHOD | SINGLE GROUP THREADED HOLE(S) |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND CONTROL 1 AND SECONDARY 6 |
| THREAD SERIES DESIGNATOR | SINGLE GROUP UNIFIED NATIONAL COARSE (UNC) |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| OVERALL LENGTH | INCHES MINIMUM 1.094 AND INCHES MAXIMUM 1.156 |
| FREQUENCY RATING | SINGLE COMPONENT KILOHERTZ MINIMUM 3.8 AND KILOHERTZ MAXIMUM 4.2 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD BROUGHT OUT TO TERMINAL |
| BODY OUTSIDE DIAMETER | INCHES MINIMUM 1.969 AND INCHES MAXIMUM 2.031 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 79.18 |
| SPECIAL FEATURES | 1 PRIMARY; 1 BIAS; & 6 SECONDARY WINDINGS |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES AC MAXIMUM 150.0 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES AC MAXIMUM 150.0 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC MAXIMUM 40.0 |
| NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.138 |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| WB01 | WB | 01-FEB-05 | WB | 81 | WB |
| YW01 | YW | 01-JAN-98 | YW | 81 | YW |
Freight
- ACTY CD
- CL
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Related items
Standardization
- Item standardization code
- 6
- Orig stdzn dec
- TX
- Dt stdzn dec
- 22-MAY-1968
- NIIN status code
- 0
Request a quote