Catalog item
Request a quoteTRANSFORMER,POWER
5950FSC
01NCB code
069-2571Item number
NIIN 01-069-2571
- DEMIL code
- A
Identification
- Item name code
- 32496
- PINC
- 0032496
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 11-DEC-78
- Precious metals indicator
- A
- Hazardous material indicator
- P
- Schedule B export code
- 8504314035
- Last known source of supply
- S9E
Part numbers
Characteristics
| RELIABILITY INDICATOR | NOT ESTABLISHED |
|---|---|
| OVERALL LENGTH | INCHES MINIMUM 2.359 AND INCHES MAXIMUM 2.391 |
| MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES MINIMUM 0.183 AND INCHES MAXIMUM 0.193 |
| FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 50.0 OR HERTZ NOMINAL 60.0 |
| INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT VOLT-AMPERE 3.1 |
| WINDING SHIELDING METHOD | SINGLE COMPONENT INTERNAL SHIELD GROUNDED TO CORE |
| BODY LENGTH | INCHES MINIMUM 1.625 AND INCHES MAXIMUM 1.657 |
| BODY WIDTH | INCHES MINIMUM 1.797 AND INCHES MAXIMUM 1.829 |
| BODY HEIGHT | INCHES MINIMUM 1.922 AND INCHES MAXIMUM 1.954 |
| DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES MINIMUM 1.995 AND INCHES MAXIMUM 2.005 |
| INCLOSURE TYPE | FULLY INCLOSED |
| MOUNTING FACILITY QUANTITY | 2 |
| MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 3 |
| FEATURES PROVIDED | COLOR CODED LEAD |
| WINDING OPERATING CURRENT | SINGLE COMPONENT THIRD SECONDARY MILLIAMPERES DC NOMINAL 1.5 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT SECOND SECONDARY MILLIAMPERES DC NOMINAL 35.0 |
| WINDING OPERATING CURRENT | SINGLE COMPONENT FIRST SECONDARY MILLIAMPERES DC NOMINAL 14.0 |
| WINDING POWER RATING | SINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 1.6 |
| WINDING POWER RATING | SINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 1.4 |
| WINDING POWER RATING | SINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 0.1 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT FIRST SECONDARY DC VOLTS NOMINAL 117.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 115.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT THIRD SECONDARY DC VOLTS NOMINAL 40.00 |
| WINDING OPERATING VOLTAGE | SINGLE COMPONENT SECOND SECONDARY DC VOLTS NOMINAL 41.00 |
| TERMINAL TYPE AND QUANTITY | WIRE LEAD W/LUG 9 |
Freight
- ACTY CD
- TX
- NMFC
- 063420
- NMFC sub
- Z
- Uniform freight class
- 35355
- Less than truckload
- W
- Water commodity code
- 595
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- TRANSFORMERS,NOI,OR TRANSFORMER PAR
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 11-DEC-1978
- NIIN status code
- 6
History
Identification changes
- Item name code
- 32496
- Item standardization code
- 5
- DEMIL code
- A
- Criticality code
- X
- Precious metals indicator
- A
- Cancelled date
- 10-JUN-2026
- NIIN status code
- 6
Past part numbers
Request a quote