Catalog item

TRANSFORMER,POWER

5950FSC
01NCB code
271-4817Item number
NIIN 01-271-4817
Request a quote
DEMIL code
A

Identification

Item name code
32496
PINC
0032496
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
26-JAN-88
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
P
Last known source of supply
SMS

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
40-054808-0130003
NAVAL AIR SYSTEMS COMMAND MANAGED ORIGINAL DESIGN ACTIVITY NOT MATERIAL/PARTS SUPPLIER
A121ZZ
40-054808-0115280
NORTHROP GRUMMAN SYSTEMS CORPORATION DIV ES DEFENSIVE SYSTEMS DIVISION
R591TXB
21001717547
ATCO TECHNOLOGY INC BULLOCK MAGNETICS DIV
H395ZZ
2100717547
ATCO TECHNOLOGY INC BULLOCK MAGNETICS DIV
H595TXB

Characteristics

RELIABILITY INDICATORNOT ESTABLISHED
OVERALL LENGTHINCHES NOMINAL 3.250
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTHALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 2.750
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTHALL MOUNTING FACILITIES ALL CENTER GROUPINGS INCHES NOMINAL 2.250
OVERALL HEIGHTINCHES NOMINAL 2.870
OVERALL WIDTHINCHES NOMINAL 3.000
FREQUENCY RATINGSINGLE COMPONENT HERTZ NOMINAL 400.0
INPUT-OUTPUT PHASE RELATIONSHIPSINGLE COMPONENT THREE PHASE TO THREE PHASE
TRANSFORMER WINDING CONNECTION TYPEDELTA-DELTA AND DELTA-WYE
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY QUANTITY4
MOUNTING METHODSECOND GROUP THREADED HOLE(S)
MOUNTING METHODFIRST GROUP THREADED STUD(S)
WINDING FUNCTION AND QUANTITYSINGLE COMPONENT PRIMARY 1 AND SECONDARY 7
NOMINAL THREAD SIZEFIRST GROUP INCHES 0.112
NOMINAL THREAD SIZESECOND GROUP INCHES 0.164
WINDING OPERATING CURRENTSINGLE COMPONENT THIRD SECONDARY AMPERES AC NOMINAL 2.61
WINDING OPERATING CURRENTSINGLE COMPONENT FOURTH SECONDARY MILLIAMPERES AC NOMINAL 730.0
WINDING OPERATING CURRENTSINGLE COMPONENT FIRST SECONDARY AMPERES AC NOMINAL 2.04
WINDING OPERATING CURRENTSINGLE COMPONENT SECOND SECONDARY AMPERES AC NOMINAL 1.63
WINDING POWER RATINGSINGLE COMPONENT SECOND SECONDARY VOLTS-AMPERES 29.34
WINDING POWER RATINGSINGLE COMPONENT FIRST SECONDARY VOLTS-AMPERES 36.72
WINDING POWER RATINGSINGLE COMPONENT THIRD SECONDARY VOLTS-AMPERES 52.22
WINDING POWER RATINGSINGLE COMPONENT FOURTH SECONDARY VOLTS-AMPERES 12.6
WINDING OPERATING VOLTAGESINGLE COMPONENT FIRST SECONDARY AC VOLTS NOMINAL 18.00
WINDING OPERATING VOLTAGESINGLE COMPONENT THIRD SECONDARY AC VOLTS NOMINAL 30.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SECOND SECONDARY AC VOLTS NOMINAL 18.00
WINDING OPERATING VOLTAGESINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 200.00
WINDING OPERATING VOLTAGESINGLE COMPONENT FOURTH SECONDARY AC VOLTS NOMINAL 18.00
SPECIAL FEATURES1 PRIMARY WINDING; 7 SECONDARY WINDINGS
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 15280-40-054808
THREAD SERIES DESIGNATORALL GROUPINGS UNIFIED NATIONAL COARSE (UNC)
TERMINAL TYPE AND QUANTITYWIRE HOOK 26

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
ZC01ZC01-APR-91ZC81ZC

Freight

ACTY CD
ZC
NMFC
063420
NMFC sub
Z
Uniform freight class
35355
Less than truckload
W
Water commodity code
595
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
TRANSFORMERS,NOI,OR TRANSFORMER PAR

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
26-JAN-1988
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.