Catalog item

AMPLIFIER,RADIO FREQUENCY

5996FSC
01NCB code
361-4972Item number
NIIN 01-361-4972
Request a quote
DEMIL code
D

Identification

Item name code
00446
PINC
0000446
Criticality code
X
II
M
DEMIL code
D
DEMIL integrity code
1
NIIN assigned
17-JUL-92
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
A
Schedule B export code
8543709610
Last known source of supply
FPZ

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNSC
8010H02F0001L7Y9
DYNAMIC WAVE TELECOM, INC.
A324ZZ
8010H02F00073293
STELLANT SYSTEMS INC
A594MBB

Characteristics

OVERALL LENGTHINCHES NOMINAL 21.240
OVERALL HEIGHTINCHES NOMINAL 3.500
OVERALL WIDTHINCHES NOMINAL 18.240
OPERATING TEMP RANGECELSIUS 0.0 TO 50.0
AVERAGE LIFE MEASUREMENTNOT RATED
BASIC SHAPE STYLE
MAXIMUM OPERATING ALTITUDE RATINGFEET 10000.0
INCLOSURE TYPEENCASED
OPERATING CONTROL METHODMANUAL
INSTALLATION DESIGNTOP OF CABINET/COUNTER AND RACK
CONTROL TYPELOCAL
CONNECTION TYPEFRONT TERMINAL STUD
CIRCUIT CONSTRUCTION TYPESOLID STATE
FREQUENCY PER CHANNELGIGAHERTZ NOMINAL OPERATING CHANNEL 4.0 AND GIGAHERTZ NOMINAL OPERATING CHANNEL 8.0
AVERAGE POWER RATING PER CHANNELWATTS OUTPUT 10.0
OVERALL GAINDECIBELS 30.0
OPERATING AC FREQUENCY IN HERTZMINIMUM SINGLE VOLTAGE 47.0 AND MAXIMUM SINGLE VOLTAGE 63.0
MAXIMUM POWER DRAIN RATINGWATTS 250.0
CONNECTION CONTACT TYPE AND QUANTITYCOAXIAL RECEPTACLE INTERNAL 1
EXTERNAL AC OPERATING VOLTAGE IN VOLTSMINIMUM SINGLE VOLTAGE 99.0 AND MAXIMUM SINGLE VOLTAGE 132.0
CUBIC MEASURECUBIC FEET 0.73
INCLOSURE MATERIALALUMINUM
PHASESINGLE
SPECIAL FEATURESFRONT PANEL CONTROLS: PRIME POWER ON/OFF,RF OPERATE/STANDBY (FAULT RESET). FRONT PANEL INDICATORS: PRIME POWER ON/STANDBY,RF OPERATE,FAULT. METERING: HELIX CURRENT. PROTECTION: PRIME POWER FUSE,WARM UP DELAY,AUTOMATIC SEQUENCING OF HIGH VOLTAGE AND BEAM CURRENT,UNATTENDED PROTECTION (HEATER SHUTDOWN AFTER FAULT COUNTER TRIP),HELIX CURRENT OVERLOAD,HIGH TEMPERATURE LOW/HIGH LINE VOLTAGE,SAFETY INTERLOCKS. EQUIPMENT CASE,IS A SELF-CONTAINED DESIGNED FOR BENCH TOP OR RACK MOUNT. AUTO RECYCLE IF POWER OUTAGE IS LESSTHAN 3 SECONDS. AUTOMATIC TURN OFF IF TWO CONSECUTIVE HELIX OVERLOAD FAULTS OCCUR:NOISE FIGURE 35DB MAX: SPURIOUS MODULATION M50DBC MAX: LOAD VSWR 2.5:1 MAX: GAIN STABILITY 0.25DB/24HRS: MAXOPERATING HUMIDITY 95PCT
RELATIONSHIP TO SIMILAR EQUIPMENT6625010346118

MOE rules

MOE rule
ZW01
MOE CD
ZW
Date assigned
01-DEC-05
PICA
ZW
PICA LOA
81
Auth collab
ZW

Freight

ACTY CD
SE

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
17-JUL-1992
NIIN status code
0

Request a quote