Catalog item
Request a quoteGENERATOR SET,DIESEL ENGINE
6115FSC
01NCB code
150-0367Item number
NIIN 01-150-0367
- DEMIL code
- A
Identification
- Item name code
- 00476
- PINC
- 0000476
- Criticality code
- X
- II
- M
- DEMIL code
- A
- NIIN assigned
- 29-MAR-83
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8503006060
- Last known source of supply
- MPB
Part numbers
| Part number | CAGE | CAGE status | RNCC | RNVC | Document availability code | RNAAC | RNSC |
|---|---|---|---|---|---|---|---|
| MEP-026B | 30554 DEPARTMENT OF DEFENSE PROJECT MANAGER-MOBILE ELECTRIC POWER | A | 3 | 2 | 4 | PA | |
| MIL-G-52732/8 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 3 | CT | B |
| MIL-G-52191 | 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M | A | 5 | 9 | 4 | CT | B |
Characteristics
| MOUNTING TYPE | SKID |
|---|---|
| OVERALL LENGTH | INCHES NOMINAL 39.000 |
| OVERALL HEIGHT | INCHES NOMINAL 28.000 |
| OVERALL WIDTH | INCHES NOMINAL 23.750 |
| CURRENT TYPE | DC |
| DIRECT CURRENT RATING IN AMPS | 0.25 AND 0.77 |
| DC VOLTAGE RATING | VOLTS NOMINAL 28.0 |
| IDENTIFYING NUMBER | TYPE NO. -E-026B |
| DC WATTAGE RATING | KILOWATTS 3.0 |
| PRIME MOVER STARTING METHOD | ELECTRIC MOTOR |
| CRANKING VOLTAGE IN VOLTS | 24.0 |
| AMBIENT TEMP IN DEG CELSIUS | M31.7 AND 51.7 |
| TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 75.0 |
| COOLING METHOD | HEAT EXCHANGE |
MOE rules
| MOE rule | MOE CD | Date assigned | PICA | PICA LOA | Auth collab |
|---|---|---|---|---|---|
| ZU01 | ZU | 01-APR-25 | ZU | 81 | ZU |
| ZW01 | ZW | 01-APR-25 | ZW | 81 | ZW |
Freight
- ACTY CD
- PA
Related items
Standardization
| Related NSN | Item standardization code | Orig stdzn dec | Dt stdzn dec | NIIN status code |
|---|---|---|---|---|
| 6115-00-017-8239 | 3 | CX | 10-AUG-1986 | 0 |
| 6115-00-759-2768 | 3 | CX | 10-AUG-1986 | 0 |
| 6115-00-519-2017 | 3 | D4 | 21-OCT-1968 | 0 |
| 6115-00-075-9123 | 3 | D4 | 05-DEC-1969 | 0 |
| 6115-00-996-5156 | 3 | CX | 10-AUG-1986 | 0 |
| 6115-00-860-2251 | 3 | D4 | 05-DEC-1969 | 0 |
| 6115-00-896-1981 | 3 | D4 | 21-OCT-1968 | 0 |
| 6115-00-799-0667 | 3 | D4 | 21-OCT-1968 | 0 |
| 6115-00-816-5929 | 3 | CX | 10-AUG-1986 | 0 |
| 6115-00-897-5704 | 3 | D4 | 21-OCT-1968 | 0 |
| 6115-00-500-2548 | 3 | D4 | 05-DEC-1969 | 0 |
| 6115-00-863-5743 | 3 | CX | 10-AUG-1986 | 0 |
| 3 | D4 | 05-DEC-1969 | 0 | |
| 3 | CX | 10-AUG-1986 | 0 | |
| 3 | D4 | 21-OCT-1968 | 0 | |
| 1 | CX | 21-AUG-1986 | 0 |
Cancelled and replaced NIINs
- FSC
- 6115
- Cancelled NIIN
- 6115-00-240-0393
- NIIN status code
- 5
- Effective date
- 22-JUL-2026
- DEMIL code
- A
Request a quote