Catalog item

CABLE,POWER,ELECTRICAL

6145FSC
00NCB code
845-0588Item number
NIIN 00-845-0588
Request a quote
DEMIL code
A

Identification

Item name code
00232
PINC
0000232
Criticality code
X
II
0
DEMIL code
A
NIIN assigned
01-JAN-62
Precious metals indicator
S
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8544606000
Last known source of supply
S9I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
E16C9-90SP81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A22EZZ
MIL-DTL-55021/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A41EZZ
EC16U9-90SP81349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59EKZB
MIL-C-55021/281349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A59EKZB
MPD150718876
US ARMY AVIATION AND MISSILE COMMAND
A51XXX3D
E16U9-90SP18876
US ARMY AVIATION AND MISSILE COMMAND
A51XXX3D

Characteristics

ROUND CONDUCTOR SIZEALL CONDUCTORS AWG 16
CONDUCTOR ARRANGEMENT AND QUANTITYTWISTED PAIR 1
CROSS-SECTIONAL SHAPE STYLE
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR ALL CONDUCTORS ASSN STD SINGLE MATERIAL RESPONSE AST- B298
PRECIOUS MATERIAL AND LOCATIONSILVER SURFACE ALL CONDUCTORS AND SILVER SURFACE SHIELD,BRAID
STRAND AWG SIZE PER CONDUCTOR29
COLORFIRST POSITION COVER ALL CONDUCTORS WHITE
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
CONDUCTOR FORMALL CONDUCTORS STRANDED
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.231
CONDUCTOR QUANTITY2
TRACER COLORFIRST TRACER SECOND CONDUCTOR BLACK
STRAND QUANTITY PER CONDUCTOR19
TEMP RATINGCELSIUS -40.0 AND CELSIUS 105.0
PRECIOUS MATERIALSILVER
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS SILVER
MATERIALFIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYTETRAFLUOROETHYLENE
SPECIAL FEATURESPRIMARY INSULATION CONFORMS TO L-P-403 TYPE 3

MOE rules

MOE ruleMOE CDDate assignedPICAPICA LOAAuth collab
YA01YA01-OCT-00YA81YA
YB01YB01-OCT-08YB81YB
ZR01ZR01-DEC-07ZR81ZR

Freight

ACTY CD
XX
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Related items

Standardization

Item standardization code
2
Orig stdzn dec
KZ
Dt stdzn dec
15-DEC-1974
NIIN status code
0

Request a quote