Catalog item

WIRE,ELECTRICAL

6145FSC
00NCB code
880-7271Item number
NIIN 00-880-7271
Request a quote
Unit price
$0.22
Unit of issue
FT
Source of supply
G69
DEMIL code
A

Identification

Item name code
00798
PINC
0000798
Criticality code
N
II
0
DEMIL code
A
NIIN assigned
01-JAN-60
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8548900100

Management

Effective date
01-OCT-2025
Major organizational entity
GE
Acquisition advice code
G
Source of supply
G69
Unit of issue
FT
Unit of measure quantity
0.0000
Unit price
$0.22
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
MIL-W-7681349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A414KZ
MW-C16(26)U881349
MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
A224KZ
1557-992194
BELDEN, INC.
A514KZ3D
8521-816428
BELDEN WIRE & CABLE COMPANY LLC DBA BELDEN CDT ELECTRONICS DIVISION
A51EKZ

Characteristics

VOLTAGE RATINGSINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 1000.0
ROUND CONDUCTOR SIZESINGLE CONDUCTOR AWG 16
MATERIAL DOCUMENT AND CLASSIFICATIONCORE CONDUCTOR SINGLE CONDUCTOR FED SPEC SINGLE MATERIAL RESPONSE QQ-W-343,SOFT
MATERIAL DOCUMENT AND CLASSIFICATIONFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR MIL SPEC SINGLE MATERIAL RESPONSE -IL-I-3930,TYE 1
SURFACE TREATMENTCORE CONDUCTOR SINGLE CONDUCTOR TIN
MATERIALCORE CONDUCTOR SINGLE CONDUCTOR COPPER
CROSS-SECTIONAL SHAPE STYLE
TEMP RATINGCELSIUS -40.0 AND CELSIUS 80.0
CROSS SECTION OUTSIDE DIAMETERINCHES NOMINAL 0.095
STRAND AWG SIZE PER CONDUCTOR30
COLORFIRST POSITION COVER SINGLE CONDUCTOR GRAY/GREY
STRAND QUANTITY PER CONDUCTOR26
CONDUCTOR FORMSINGLE CONDUCTOR STRANDED
END ITEM IDENTIFICATIONGENERAL APPLICATION-CABLE(GEN-AP-C)
MATERIALFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC POLYVINYL CHLORIDE (PVC)

MOE rules

MOE rule
B481
MOE CD
GE
AMC
1
AMSC
H
Date assigned
01-DEC-00
PICA
48
PICA LOA
02
Auth collab
48

Freight

ACTY CD
XX
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
658
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Packaging

Unit and preservation

PICA SICA
P
PKG cat
27A0
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
Intermediate container qty
000
No intermediate container quantity specified (000)
Method of preservation
22
Clng drying
X
Pres mat
XX
Wrap mat
XX
Cush dun
XX
THK
X
Unit cont
XX
PKG data source
A

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
00
No requirement.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Lvl c
X
Unit pack weight
0.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.0010
OPI
M
All packaging data is mandatory for compliance and no substitutions are permitted.
Supplemental instructions
SPECIAL QUP CODE ZZZ = 1000 FT.

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
6
Orig stdzn dec
KZ
Dt stdzn dec
11-JUN-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.