Catalog item
Request a quoteCABLE,SPECIAL PURPOSE,ELECTRICAL
6145FSC
01NCB code
407-1696Item number
NIIN 01-407-1696
- Unit price
- $10.97
- Unit of issue
- FT
- Source of supply
- SMS
- DEMIL code
- A
Identification
- Item name code
- 16488
- PINC
- 0016488
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 22-JAN-95
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
- Schedule B export code
- 8548900100
- FedMall
- Y
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-2026 | DN | J | SMS | FT | 0.0000 | $10.97 | 1 | U | 0 | 9B----- | $0.00 | N |
| 01-OCT-2026 | DS | J | SMS | FT | 0.0000 | $10.97 | 1 | U | 0 | ------- | $0.00 | I |
Part numbers
Characteristics
| CROSS-SECTIONAL SHAPE STYLE | |
|---|---|
| TEMP RATING | CELSIUS -28.0 AND CELSIUS 65.0 |
| CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.665 |
| CONDUCTOR QUANTITY | 9 |
| STRAND QUANTITY PER CONDUCTOR | 19 |
| STRAND QUANTITY PER CONDUCTOR | 7 |
| CONDUCTOR FORM | SINGLE CONDUCTOR STRANDED |
| ROUND CONDUCTOR SIZE | FIRST CONDUCTOR AWG 22 |
| ROUND CONDUCTOR SIZE | FOURTH CONDUCTOR AWG 16 |
| ROUND CONDUCTOR SIZE | FIFTH CONDUCTOR AWG 16 |
| ROUND CONDUCTOR SIZE | SECOND CONDUCTOR AWG 22 |
| ROUND CONDUCTOR SIZE | SIXTH CONDUCTOR AWG 16 |
| ROUND CONDUCTOR SIZE | EIGHTH CONDUCTOR AWG 18 |
| ROUND CONDUCTOR SIZE | SEVENTH CONDUCTOR AWG 18 |
| ROUND CONDUCTOR SIZE | THIRD CONDUCTOR AWG 16 |
| STRAND AWG SIZE PER CONDUCTOR | 26 |
| STRAND AWG SIZE PER CONDUCTOR | 30 |
| STRAND AWG SIZE PER CONDUCTOR | 29 |
| CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 2 AND TWISTED PAIR 2 AND TRIPLES 1 |
| GROUP QUANTITY | 4 |
| CONDUCTOR SEQUENCE WITHIN GROUPS | FIRST GROUP FIRST CONDUCTOR AND SECOND CONDUCTOR |
| CONDUCTOR SEQUENCE WITHIN GROUPS | FOURTH GROUP SEVENTH CONDUCTOR AND EIGHTH CONDUCTOR AND NINTH CONDUCTOR |
| CONDUCTOR SEQUENCE WITHIN GROUPS | SECOND GROUP THIRD CONDUCTOR AND FOURTH CONDUCTOR |
| CONDUCTOR SEQUENCE WITHIN GROUPS | THIRD GROUP FIFTH CONDUCTOR AND SIXTH CONDUCTOR |
| COLOR | FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR BROWN |
| COLOR | FIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR GREEN |
| COLOR | FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR BLACK |
| COLOR | FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR WHITE |
| COLOR | FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR GREEN |
| COLOR | FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR RED |
| COLOR | FIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR ORANGE |
| COLOR | FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR YELLOW |
| COLOR | FIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR YELLOW |
| MATERIAL | SECOND POSITION SHIELD BRAID METALLIC FIRST CONDUCTOR COPPER |
| MATERIAL | FIRST POSITION PRIMARY INSULATION FIRST CONDUCTOR PLASTIC, POLYETHYLENE (PP) |
| MATERIAL | SECOND POSITION SHIELD BRAID METALLIC SECOND CONDUCTOR COPPER |
| MATERIAL | THIRD POSITION TAPE FIRST CONDUCTOR PLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) |
| MATERIAL | FIRST POSITION PRIMARY INSULATION THIRD CONDUCTOR PLASTIC POLYPROPYLENE |
| MATERIAL | FIFTH POSITION SHIELD BRAID METALLIC THIRD GROUP COPPER |
| MATERIAL | FIRST POSITION PRIMARY INSULATION NINTH CONDUCTOR PLASTIC POLYPROPYLENE |
| MATERIAL | FIRST POSITION PRIMARY INSULATION FIFTH CONDUCTOR PLASTIC POLYPROPYLENE |
| MATERIAL | THIRD POSITION TAPE SECOND CONDUCTOR PLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) |
| MATERIAL | FOURTH POSITION TAPE ALL GROUPS PLASTIC POLYETHYLENE TEREPHTHALATE (PET)(POLYESTER) |
| MATERIAL | FIRST POSITION PRIMARY INSULATION SIXTH CONDUCTOR PLASTIC POLYPROPYLENE |
| MATERIAL | SIXTH POSITION JACKET CABLE PLASTIC POLYURETHANE |
| MATERIAL | FIRST POSITION PRIMARY INSULATION FOURTH CONDUCTOR PLASTIC POLYPROPYLENE |
| MATERIAL | FIRST POSITION PRIMARY INSULATION EIGHTH CONDUCTOR PLASTIC POLYPROPYLENE |
| MATERIAL | FIRST POSITION PRIMARY INSULATION SECOND CONDUCTOR PLASTIC, POLYETHYLENE (PP) |
| MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
| MATERIAL | FIRST POSITION PRIMARY INSULATION SEVENTH CONDUCTOR PLASTIC POLYPROPYLENE |
| SURFACE TREATMENT | SECOND POSITION SHIELD BRAID METALLIC SECOND CONDUCTOR TIN |
| SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| SURFACE TREATMENT | SECOND POSITION SHIELD BRAID METALLIC FIRST CONDUCTOR TIN |
| SURFACE TREATMENT | THIRD POSITION SHIELD BRAID METALLIC THIRD GROUP TIN |
MOE rules
- MOE rule
- N9BN
- MOE CD
- DN
- AMC
- 0
- AMSC
- 0
- Date assigned
- 01-NOV-05
- IMC
- Z
- IMCA
- GH
- PICA
- GX
- PICA LOA
- 01
- SICA
- GH
- SICA LOA
- 5D
- Auth collab
- GX
- Supp collab
- HD
- Fmr MOE rl
- N9ND
Service data
Navy
- COG
- 9B
Freight
- ACTY CD
- KZ
- NMFC
- 030310
- NMFC sub
- Z
- Uniform freight class
- 15080
- Less than truckload
- W
- Water commodity code
- 743
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- HZ
- NMF description
- CABLE OR WIRE
Related items
Standardization
- Item standardization code
- 5
- Orig stdzn dec
- 97
- Dt stdzn dec
- 22-JAN-1995
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.