Catalog item

WIRE,ELECTRICAL

6145FSC
01NCB code
721-3188Item number
NIIN 01-721-3188
Request a quote
Unit price
$205.00
Unit of issue
FT
Source of supply
SMS
DEMIL code
A

Identification

Item name code
00798
PINC
0000798
Criticality code
X
II
N
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
06-JUN-24
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
ESD/EMI code
A
Schedule B export code
8548900100

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-OCT-2025DFJSMSFT0.0000$205.000U0NSF9---N$0.00F
01-OCT-2025DSJSMSFT0.0000$205.000U0-------$0.00I

Part numbers

Part number
BMS13-48T10C02G022
CAGE
81205
THE BOEING COMPANY DIV DEFENSE
CAGE status
A
RNCC
3
RNVC
1
Document availability code
D
RNAAC
9Z
RNFC
4
RNSC
A

Characteristics

CROSS-SECTIONAL SHAPE STYLE
INSIDE DIAMETERALL CONDUCTORS INCHES NOMINAL 0.0293
TEMP RATINGCELSIUS -65.0 AND CELSIUS 150.0
OUTSIDE DIAMETEROVERALL INCHES NOMINAL 0.091
END ITEM IDENTIFICATIONKC-46A TANKER AIRCRAFT/AIRFRAME
STRAND QUANTITY PER CONDUCTOR19
CONDUCTOR FORMOVERALL STRANDED
PART NAME ASSIGNED BY CONTROLLING AGENCYWIRE, ELECTRIC, EXTRUDED CROSS-LINKED ETHYLENETETRAFLUOROETHYLENE, (ETFE) 600 V (RMS) 150 C
ROUND CONDUCTOR SIZEOVERALL AWG 22.0
STRAND AWG SIZE PER CONDUCTOR34
CONDUCTOR CROSS-SECTIONAL SHAPESECOND WINDING TUBULAR SOLID
VOLTAGE RATINGALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
VOLTAGE RATINGSINGLE CONDUCTOR MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 600.0
SPECIAL FEATURESCONTRACT NUMBER: FA8625-11-C-6600. ITEM IS FAA CERTIFIED. WIRE AND CABLE THAT HAS STANDARD INSULATION OR JACKET COLOR. 8 MIL INSULATION THICKNESS. ETHYLENETETRAFLUOROETHYLENE (ETFE) RESIN INSULATION. ANNEALED COPPER WITH TIN COATING. OP TEMP: -65.0 TO 150.0 DEG C. TYPE 10 - WIRE OR CABLE DUAL EXTRUSION - 8 MIL INSULATION, TIN-COATED COPPER CONDUCTOR. ONE INSULATED CONDUCTOR OR TWO OR MORE INSULATED CONDUCTORS LAID IN A SUITABLE SPIRAL TO MAKE A MULTICONDUCTOR CABLE. CLASS 02 - TWO SPIRALLY LAID WIRES (TWISTED-PAIR). 100 FOOT.
MATERIALCORE CONDUCTOR ALL CONDUCTORS COPPER
MATERIALCORE CONDUCTOR SINGLE CONDUCTOR COPPER
MATERIALCORE PRIMARY INSULATION ALL CONDUCTORS PLASTIC CROSS-LINKED ETHYLENE TETRAFLUOROETHYLENE
MATERIALFIRST POSITION PRIMARY INSULATION SINGLE CONDUCTOR PLASTIC ETHYLENE-TETRAFLUOROETHYLENE
PROPRIETARY CHARACTERISTICSPACS
SURFACE TREATMENTCORE CONDUCTOR ALL CONDUCTORS TIN
SURFACE TREATMENTCORE CONDUCTOR SINGLE CONDUCTOR TIN
NONDEFINITIVE SPEC/STD DATATYPE 10 AND CLASS 02
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSITEM IS FAA CERTIFIED

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collab
ZA01ZA01-DEC-24ZA81ZA
ZE01ZE01-JUN-24ZE81ZE
FXGXDF0001-OCT-25ZSXGX01SX5DGX TU

Service data

Air Force

Fund
SF
Budget
9
PVC
N
ERRC
N

Freight

ACTY CD
ZE
NMFC
030310
NMFC sub
Z
Uniform freight class
15080
Less than truckload
W
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
CABLE OR WIRE

Related items

Standardization

Item standardization code
5
Orig stdzn dec
97
Dt stdzn dec
06-JUN-2024
NIIN status code
0