Catalog item
Request a quoteMULTIMETER
6625FSC
01NCB code
085-6858Item number
NIIN 01-085-6858
- DEMIL code
- A
Identification
- Item name code
- 00794
- PINC
- 0000794
- Criticality code
- X
- II
- 0
- DEMIL code
- A
- NIIN assigned
- 12-NOV-79
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- P
- ESD/EMI code
- A
- Schedule B export code
- 9030908030
- Last known source of supply
- XZZ
Part numbers
- Part number
- AM-3
- CAGE
- 15566CORE INDUSTRIES INC AMPROBE INSTRUMENT DIV
- CAGE status
- H
- RNCC
- 3
- RNVC
- 9
- Document availability code
- 4
- RNAAC
- SB
- RNFC
- 4
- RNSC
- D
Characteristics
| CIRCUIT CURRENT FOR WHICH DESIGNED | DC |
|---|---|
| OVERALL LENGTH | INCHES NOMINAL 3.250 |
| OVERALL HEIGHT | INCHES NOMINAL 7.500 |
| OVERALL WIDTH | INCHES NOMINAL 5.250 |
| INDICATOR TYPE | DIAL W/POINTER |
| INSTALLATION DESIGN | BENCH |
| ACCURACY IN PERCENT | SINGLE INDICATOR EIGHTEENTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR ELEVENTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR FOURTH RANGE AT FULL SCALE -4.0 TO 4.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR THIRD RANGE AT FULL SCALE -4.0 TO 4.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR FIFTEENTH RANGE AT FULL SCALE -5.0 TO 5.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR NINETEENTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR THIRTEENTH RANGE AT FULL SCALE -5.0 TO 5.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR TWELFTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR TENTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR SIXTEENTH RANGE AT FULL SCALE -5.0 TO 5.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR SEVENTEENTH RANGE AT FULL SCALE -5.0 TO 5.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR FOURTEENTH RANGE AT FULL SCALE -5.0 TO 5.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR FIFTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR EIGHTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR NINTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR FIRST RANGE AT FULL SCALE -4.0 TO 4.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR SECOND RANGE AT FULL SCALE -4.0 TO 4.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR SIXTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR TWENTIETH RANGE AT FULL SCALE -3.0 TO 3.0 |
| ACCURACY IN PERCENT | SINGLE INDICATOR SEVENTH RANGE AT FULL SCALE -3.0 TO 3.0 |
| POWER SOURCE | INTERNAL |
| SCALE GRADUATION TYPE | SINGLE INDICATOR ALL RANGES NONLINEAR |
| MEASUREMENT RANGE | SINGLE INDICATOR FIFTH RANGE VOLTS, DC 0.0 TO 3.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR SIXTEENTH RANGE MILLIAMPERES, AC 0.0 TO 1.5 |
| MEASUREMENT RANGE | SINGLE INDICATOR FIRST RANGE VOLTS, AC 0.0 TO 30.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR EIGHTEENTH RANGE MILLIVOLTS, DC 0.0 TO 75.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR ELEVENTH RANGE OHMS 0.0 TO 50000.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR FOURTH RANGE VOLTS, AC 0.0 TO 750.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR NINTH RANGE OHMS 0.0 TO 500.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR SEVENTEENTH RANGE MILLIAMPERES, AC 0.0 TO 150.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR SIXTH RANGE VOLTS, DC 0.0 TO 30.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR THIRD RANGE VOLTS, AC 0.0 TO 300.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR TWELFTH RANGE MEGOHMS 0.0 TO 5.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR EIGHTH RANGE VOLTS, DC 0.0 TO 300.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR FOURTEENTH RANGE MICROAMPERES, AC 0.0 TO 15.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR SECOND RANGE VOLTS, AC 0.0 TO 150.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR TENTH RANGE OHMS 0.0 TO 5000.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR TWENTIETH RANGE MILLIVOLTS, DC 0.0 TO 1500.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR NINETEENTH RANGE MILLIVOLTS, DC 0.0 TO 750.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR THIRTEENTH RANGE MICROAMPERES, AC 0.0 TO 10.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR FIFTEENTH RANGE MICROAMPERES, AC 0.0 TO 150.0 |
| MEASUREMENT RANGE | SINGLE INDICATOR SEVENTH RANGE VOLTS, DC 0.0 TO 150.0 |
| SCALE SELECTION METHOD | SWITCH |
| FEATURES PROVIDED | PORTABLE |
| MOVEMENT SUSPENSION METHOD | TAUT BAND |
| OPERATING VOLTAGE RATING IN VOLTS | DC NOMINAL 1.5 |
| FUNCTIONAL CLASSIFICATION | AA1.4 |
| SPECIAL FEATURES | ALL RANGE PROTECTION; MIRROR SCALE,THREE COLOR-CODED SCALE/SWITCH PLATES; MOLDED CASE; FULLY INSULATED; SELF-LOCKING,METER STAND HANDLE; ALL-WEATHER TEST LEADS; MTC-2 ALLIGATOR CLIP ADAPTORS; USES 2 C BATTERIES; WT 2.25 LBS; DC VOLT RANGE 0 TO 300 |
| STYLE DESIGNATOR |
MOE rules
- MOE rule
- ZC01
- MOE CD
- ZC
- Date assigned
- 01-APR-91
- PICA
- ZC
- PICA LOA
- 81
- Auth collab
- ZC
Freight
- ACTY CD
- SE
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- TX
- Dt stdzn dec
- 12-AUG-1983
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.