| OVERALL DEPTH | INCHES NOMINAL 80.000 |
|---|---|
| OVERALL HEIGHT | INCHES NOMINAL 28.000 |
| OVERALL WIDTH | INCHES NOMINAL 44.000 |
| CURRENT TYPE | AC |
| FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| COMPARTMENT QUANTITY | 2 |
| END ITEM IDENTIFICATION | TF34-GE100,CONTROL AMPLIFIER |
| VOLTAGE RATING | VOLTS NOMINAL 440.0 |
| PHASE | THREE |
| SPECIAL FEATURES | CONDITIONING CHAMBER; INTERIOR DIMENSION 57 CUBIC FEET; UNIT CONSISTS OF SEPERATE HOT AND COLD CHAMBERS WITH A TEMP RANGE OF -65 DEG F TO 250 DEG F WITH A 5 DEG F VARIATION |