Catalog item
Request a quoteWINCH,DRUM,POWER OPERATED
3950FSC
00NCB code
391-9487Item number
NIIN 00-391-9487
- DEMIL code
- A
Identification
- Item name code
- 04575
- PINC
- 0004575
- Criticality code
- X
- II
- M
- DEMIL code
- A
- DEMIL integrity code
- 1
- NIIN assigned
- 01-JAN-63
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
Part numbers
Characteristics
| FREQUENCY IN HERTZ | 60.0 |
|---|---|
| FURNISHED ITEMS AND QUANTITY | MOTOR CONTROLLER 1 |
| TRAVEL RATE PER MINUTE | FEET 15.0 |
| DUTY CYCLE | INTERMITTENT |
| CURRENT TYPE | AC |
| LARGEST DIAMETER | FIRST SPOOL INCHES NOMINAL 24.000 |
| VOLTAGE IN VOLTS | 440.0 |
| DIAMETER | FIRST DRUM INCHES NOMINAL 24.000 |
| DIAMETER | SECOND DRUM INCHES NOMINAL 24.000 |
| POWER REQUIREMENT RATING | HORSEPOWER 20.00 |
| DRUM SURFACE DESIGN | GROOVED |
| PRIME MOVER QUANTITY | 1 |
| OVERALL LENGTH | FIRST SPOOL INCHES NOMINAL 20.875 |
| OVERALL LENGTH | SECOND SPOOL INCHES NOMINAL 20.875 |
| CAPSTAN SPOOL SURFACE DESIGN | PLAIN |
| CAPSTAN SPOOL QUANTITY | 2 |
| ENVIRONMENTAL PROTECTION | SPLASH TIGHT |
| OPERATION METHOD | POWERED |
| PHASE | THREE |
| LARGEST DIAMETER | SECOND SPOOL INCHES NOMINAL 24.000 |
| PRIME MOVER TYPE | ELECTRIC MOTOR |
| INCLOSURE TYPE | FULLY INCLOSED |
| COOLING METHOD | NONVENTILATED |
| CAPSTAN SPOOL MOUNTING POSITION | HORIZONTAL |
MOE rules
- MOE rule
- ZW01
- MOE CD
- ZW
- Date assigned
- 01-NOV-98
- PICA
- ZW
- PICA LOA
- 81
- Auth collab
- ZW
Freight
- ACTY CD
- XX
- NMFC
- 116440
- NMFC sub
- Z
- Uniform freight class
- 59570
- Less than truckload
- W
- Less than carload
- M
- Water commodity code
- 885
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- BZ
- NMF description
- CAPSTANS/WINCHES/WINDLASSES
Packaging
Unit and preservation
- PICA SICA
- P
- PKG cat
- ZZZZ
- Unpackaged weight
- 0.0000
- Unpackaged width
- 0.000
- Unpackaged length
- 0.000
- Unpackaged height
- 0.000
- TOS
- B
- Intermediate container qty
- 000No intermediate container quantity specified (000)
- Method of preservation
- ZZSpecial requirements apply that are not represented by the code symbols; details are provided with the acquisition...
- Clng drying
- ZSpecial requirements - See specific instructions or drawings provided.
- Pres mat
- ZZSpecial requirement – See specific instructions or drawings provided
- Wrap mat
- ZZSpecial requirements – see specific instructions or drawings provided
- Cush dun
- ZZSpecial requirements.
- THK
- ZSpecial requirements – See specific instructions or drawings provided
- Unit cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- PKG data source
- A
Unit pack
- PICA SICA
- P
- SPC MKG
- 00No special marking
- Inter cont
- ZZSpecial requirement – See specific instructions or drawings provided.
- UCL
- OUnit container is not an acceptable shipping container.
- Lvl A
- EPacking shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
- Lvl b
- QPacking shall be accomplished in accordance with table C-II for the packing level specified.
- Lvl c
- Q
- Unit pack weight
- 0.0000
- UP SZ MAXB
- 0.00000
- UP SZ MAXL
- 0.00000
- UP SZ MAXH
- 0.00000
- Unit pack cube
- 0.0000
- OPI
- MAll packaging data is mandatory for compliance and no substitutions are permitted.
- Supplemental instructions
- ZZ = PACKAGING UPDATE REQUIRED
Packaging instructions
- PICA SICA
- P
- SPI date
- 00000
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- AX
- Dt stdzn dec
- 29-FEB-1972
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.