Catalog item
Request a quoteAIR CONDITIONER
4120FSC
01NCB code
030-6883Item number
NIIN 01-030-6883
- Unit price
- $6,200.00
- Unit of issue
- EA
- Source of supply
- B16
- DEMIL code
- A
Identification
- Item name code
- 06486
- PINC
- 0006486
- Criticality code
- N
- II
- M
- DEMIL code
- A
- NIIN assigned
- 10-NOV-76
- Precious metals indicator
- A
- ADP equipment code
- 0
- Hazardous material indicator
- N
Management
| Effective date | Major organizational entity | Acquisition advice code | Source of supply | Unit of issue | Unit of measure quantity | Unit price | Quantity per unit pack | Controlled inventory item code | Shelf-life code | Recoverability code | Management control | Net price | USC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01-OCT-1997 | DA | J | B16 | EA | 0.0000 | $6,200.00 | 1 | U | 0 | H | GQ1W5N- | $0.00 | L |
| 01-FEB-2026 | DN | J | NRP | EA | 0.0000 | $39,117.00 | 1 | U | 0 | H | 7G--009 | $2,630.00 | N |
Part numbers
Characteristics
| MOUNTING TYPE | FLOOR |
|---|---|
| CURRENT TYPE | AC |
| FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| USAGE DESIGN | COMPRESSOR,EVAPORATOR FAN,,CONDENSER FAN |
| VOLTAGE RATING | VOLTS NOMINAL 208.0 |
| COOLANT TYPE | FREON-22 |
| ELECTRIC MOTOR QUANTITY | 3 |
| POWER SOURCE | ELECTRIC MOTOR |
| CONDENSER COOLING TYPE | AIR |
| COMPRESSOR UNIT TYPE | HERMETICALLY SEALED |
| NOMINAL COOLING CAPACITY | CUBIC FEET PER MINUTE 1080.0 |
| COOLING CAPACITY IN BTU PER HOUR | NOMINAL 25000.0 |
| HEATING CAPACITY IN BTU PER HOUR | NOMINAL 15000.0 |
| PHASE | THREE |
| SPECIAL FEATURES | COOLING TOWER-NOT INCL.;EVAPORATOR CONDENSER-NOT INCL.;1ST MOTOR-4.000 HP,2ND MOTOR-0.500 HP,3RD MOTOR-1.500 HP;ACCESSORIES-NOT INCL.;CABINET MATL-ALUM. ALLOY |
| SURFACE TREATMENT | ENAMEL |
MOE rules
| MOE rule | MOE CD | AMC | AMSC | NIMSC | Date assigned | IMC | PICA | PICA LOA | SICA | SICA LOA | Auth collab | Supp collab | DSOR | Fmr MOE rl |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| A502 | DA | 3 | H | A | 01-OCT-97 | D | CL | 22 | CL | TO | A002 | |||
| NSLL | DN | 3 | H | 3 | 01-OCT-97 | D | CL | 22 | HD | 8D | CL HD | GG | TO | NSBB |
Service data
Army
- Matcat 1
- G
- Matcat 2
- Q
- Matcat 3
- 1
- Matcat 4 5
- W5
- ARC
- N
Navy
- COG
- 7G
- IRRC
- 00
- SMCC
- 9
Freight
- ACTY CD
- AJ
- NMFC
- 114115
- NMFC sub
- Z
- Uniform freight class
- 00000
- Less than truckload
- W
- Less than carload
- M
- RVC
- 1
- Water commodity code
- 658
- Type of cargo code
- Z
- Special handling code
- 9
- Air dimension code
- A
- Air commodity code
- VZ
- NMF description
- AC, DEHU, WASHERSM BLOWERS, PARTS
Packaging
Unit and preservation
| PICA SICA | PKG cat | Unpackaged weight | Unpackaged width | Unpackaged length | Unpackaged height | Unit of issue | TOS | Intermediate container qty | Method of preservation | Clng drying | Pres mat | Wrap mat | Cush dun | THK | Unit cont | PKG data source |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S | ZZZ0 | 0.0000 | 0.000 | 0.000 | 0.000 | EA | B | 000 No intermediate container quantity specified (000) | 10 Physical protection | 1 Any suitable process that is not injurious to the item. | 00 No requirement | FA MIL-P-130, laminated and creped wrapping paper | 00 No requirement | 0 Not applicable | EC ASTM D5118/D5118M, Type CF, Class domestic, corrugated fiberboard box. | A |
| P | 0.0000 | 0.000 | 0.000 | 0.000 | EA | ZZ Special requirements apply that are not represented by the code symbols; details are provided with the acquisition... | Z Special requirements - See specific instructions or drawings provided. | ZZ Special requirement – See specific instructions or drawings provided | ZZ Special requirements – see specific instructions or drawings provided | ZZ Special requirements. | Z Special requirements – See specific instructions or drawings provided | FU ASTM D6256/D6256M, wood-cleated skidded box, load bearing base. | A |
Unit pack
| PICA SICA | SPC MKG | Inter cont | UCL | Lvl A | Lvl b | Lvl c | Unit pack weight | UP SZ MAXB | UP SZ MAXL | UP SZ MAXH | Unit pack cube | OPI | Supplemental instructions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| S | 24 Open for inspection or use only | 00 No requirement. | O Unit container is not an acceptable shipping container. | E Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,... | Q Packing shall be accomplished in accordance with table C-II for the packing level specified. | Q | 0.0000 | 38.00000 | 48.00000 | 69.00000 | 72.8330 | M All packaging data is mandatory for compliance and no substitutions are permitted. | |
| P | 00 No special marking | 00 No requirement. | 0.0000 | 0.00000 | 0.00000 | 0.00000 | 0.0000 | A Packaging is in accordance with a procedural specification or an SPI. | PRSV IAW MIL-R-3593 |
Packaging instructions
| PICA SICA | SPI date |
|---|---|
| S | 00000 |
| P | 00000 |
Related items
Standardization
- Item standardization code
- 2
- Orig stdzn dec
- CX
- Dt stdzn dec
- 30-SEP-1978
- NIIN status code
- 0
Request a quote
Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.