Catalog item

FAN,VANEAXIAL

4140FSC
00NCB code
107-8185Item number
NIIN 00-107-8185
Request a quote
Unit price
$8,688.01
Unit of issue
EA
Source of supply
SMS
DEMIL code
A

Identification

Item name code
04245
PINC
0004245
Criticality code
X
II
0
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-DEC-72
Precious metals indicator
U
Hazardous material indicator
N
Schedule B export code
8414599080

Management

Effective date
01-OCT-2026
Major organizational entity
DS
Acquisition advice code
J
Source of supply
SMS
Unit of issue
EA
Unit of measure quantity
0.0000
Unit price
$8,688.01
Quantity per unit pack
1
Controlled inventory item code
U
Shelf-life code
0
Management control
-------
Net price
$0.00
USC
I

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
23430-155820
RTX CORPORATION DIV PRATT & WHITNEY
A325ZZ
23430-199167
HAMILTON SUNDSTRAND CORPORATION
A595CXB
2890762-110001
NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT MATERIAL/PARTS SUPPLIER
A72ACX3D
M6671H-1A118965
DYNAMIC AIR ENGINEERING, INC. DIV DAE SYSTEMS
A325CX
M6671HA18965
DYNAMIC AIR ENGINEERING, INC. DIV DAE SYSTEMS
A595CX3B

Characteristics

ENVIRONMENTAL PROTECTIONCORROSION RESISTANT AND DUSTPROOF AND FUNGUS RESISTANT AND HUMIDITY PROOF AND MOISTURE RESISTANT AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF
INCLOSURE TYPEFULLY INCLOSED
MOUNTING FACILITY TYPE AND QUANTITYFLANGE 1
PRIME MOVER TYPEELECTRIC MOTOR
FLOW DIRECTIONINWARD
PHASETHREE
LENGTHINCHES MINIMUM 8.370 AND INCHES MAXIMUM 8.490
OPERATING SPEED AT RATED CAPACITY IN RPM11000.0
ELECTRICAL CONNECTION TYPECORD W/ATTACHED PLUG
STATIC PRESSURE AT SPECIFIED AIR FLOW RATEINCHES OF WATER (INH20) 5.0
DRIVE TYPEDIRECT
FREQUENCY IN HERTZ400.0
MATERIALOVERALL ALUMINUM
SURFACE TREATMENTOVERALL PAINT
STYLE DESIGNATOR
TEST DATA DOCUMENTDRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 10001-2890762-1
SPEED ADJUSTMENTSSINGLE SPEED
AMBIENT TEMP AT FULL RATED POWERCELSIUS -28.0 AND CELSIUS 65.0
PRIME MOVER POWER RATINGWATTS 977.500
HOUSING INSIDE DIAMETERINCHES NOMINAL 7.500
PRIME MOVER DRIVE SHAFT BEARING TYPEBALL
AIR FLOW RATECUBIC FEET PER MINUTE NOMINAL 1100.0
VOLTAGE IN VOLTS AND CURRENT TYPEAC 115.0
ROTATION DIRECTION FOR WHICH DESIGNEDCLOCKWISE

MOE rules

MOE ruleMOE CDAMCAMSCDate assignedPICAPICA LOAAuth collab
YB01YB01-APR-91YB81YB
ZG01ZG01-APR-91ZG81ZG
ZJ01ZJ01-MAR-25ZJ81ZJ
ZP01ZP01-APR-91ZP81ZP
ZR01ZR01-JUL-97ZR81ZR
ZU01ZU01-APR-91ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
DGX1DS1H01-NOV-25GX01GX

Freight

ACTY CD
CX
NMFC
061700
NMFC sub
Z
Uniform freight class
34580
Less than truckload
W
Water commodity code
72E
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HZ
NMF description
ELEC APPLIANCES/INSTRUMENTS NOI

Packaging

Unit and preservation

PICA SICA
P
PKG cat
60ZZ
Unpackaged weight
0.0000
Unpackaged width
0.000
Unpackaged length
0.000
Unpackaged height
0.000
TOS
B
Intermediate container qty
AAA
Quantity set by MIL-STD-2073-1E B.5: up to 100 unit packs, a maximum net load of 40 pounds, and a maximum of 1.5...
Method of preservation
31
Waterproof bag, heat sealed
Clng drying
1
Any suitable process that is not injurious to the item.
Pres mat
00
No requirement
Wrap mat
00
No requirement
Cush dun
ZZ
Special requirements.
THK
C
3/4 inch thick
Unit cont
D3
PPP-B-566, PPP-B-676, or ASTM D5118/D5118M, folding, setup or fiberboard box.
PKG data source
P

Unit pack

PICA SICA
P
SPC MKG
00
No special marking
Inter cont
ZZ
Special requirement – See specific instructions or drawings provided.
Lvl A
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Lvl b
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Unit pack weight
13.0000
UP SZ MAXB
0.00000
UP SZ MAXL
0.00000
UP SZ MAXH
0.00000
Unit pack cube
0.8500
OPI
O
Options can be exercised as to specific method of preservation or DoD approved packaging materials to be used.
Supplemental instructions
DGSC HAS WAIVED THE REQUIR

Packaging instructions

PICA SICA
P
PKG design ACTY
14153
SPI date
00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
CX
Dt stdzn dec
24-MAY-1976
NIIN status code
0