Catalog item

VACUUM PUMP UNIT,ROTARY

4310FSC
00NCB code
323-8866Item number
NIIN 00-323-8866
Request a quote
Unit price
$3,914.00
Unit of issue
EA
Source of supply
FLZ
DEMIL code
A

Identification

Item name code
29904
PINC
0029904
Criticality code
X
II
M
DEMIL code
A
DEMIL integrity code
1
NIIN assigned
24-NOV-73
Precious metals indicator
A
ADP equipment code
0
Hazardous material indicator
N
Schedule B export code
8414100000
IUID indicator
Y

Management

Effective dateMajor organizational entityAcquisition advice codeSource of supplyUnit of issueUnit of measure quantityUnit priceQuantity per unit packControlled inventory item codeShelf-life codeRecoverability codeManagement controlNet priceUSC
01-FEB-2020DFVFLZEA0.0000$3,914.001U0U--M---X$0.00L
01-FEB-2026DNJNRPEA0.0000$8,613.001U0H7EHB009$2,500.00N

Part numbers

Part numberCAGECAGE statusRNCCRNVCDocument availability codeRNAACRNFCRNSC
80539033781
TUTHILL CORPORATION DBA TUTHILL VAC & BLOWER SYSTEMS DIV TUTHILL VACUUM SYSTEMS
H592SB3B
80650233781
TUTHILL CORPORATION DBA TUTHILL VAC & BLOWER SYSTEMS DIV TUTHILL VACUUM SYSTEMS
H592SB3B
KTC21A33781
TUTHILL CORPORATION DBA TUTHILL VAC & BLOWER SYSTEMS DIV TUTHILL VACUUM SYSTEMS
H395SB3D

Characteristics

DISCHARGE CONNECTION QUANTITY1
GAS FOR WHICH DESIGNEDAIR
VACUUM RATINGMILLITORR 1.0
DISCHARGE CONNECTION TYPETHREADED INTERNAL
PUMPING ELEMENT TYPEROTARY PISTON
VAPOR CONDENSATION PREVENTATIVE DEVICEGAS BALLAST VALVING
AIR DISPLACEMENT RATECUBIC FEET PER MINUTE IN FREE AIR 14.0
SYSTEM DESIGNNONCORROSIVE
PRIME MOVER TYPEELECTRIC MOTOR
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATORNPT 1.000-11-1 TO 2
CONTROL DEVICE TYPEMOTOR STARTER
SAFETY DEVICE TYPEHIGH TEMPERATURE SHUTDOWN SWITCH
FEATURES PROVIDEDFUNGUS RESISTANT TREATMENT AND SEPARATOR TANK
VOLTAGE IN VOLTS230.0 AND 460.0
PHASETHREE
FREQUENCY IN HERTZ60.0
OVERALL LENGTHINCHES NOMINAL 42.000
OVERALL HEIGHTINCHES NOMINAL 28.000
OVERALL WIDTHINCHES NOMINAL 30.000
INTAKE CONNECTION QUANTITY2
STAGE QUANTITY2
DRIVE CONNECTION TYPERIGID COUPLED
PUMP QUANTITY1
BRAKE HORSEPOWER REQUIRED1.500
CURRENT TYPEAC
COOLING MEDIUMAIR AND OIL
MOUNTING TYPETRAILER

MOE rules

MOE ruleMOE CDAMCAMSCNIMSCDate assignedIMCIMCAPICAPICA LOASICASICA LOAAuth collabSupp collabDSOR
ZH01ZH01-APR-91ZH81ZH
ZU01ZU01-MAR-08ZU81ZU
ZW01ZW01-NOV-05ZW81ZW
ZX01ZX01-FEB-14ZX81
FGG4DF3UF01-APR-91DTGTG22TUFR
NSGSDN3U101-AUG-02DTG22HD8DHD TUGG00

Management phrases

Major organizational entityUSCPhrase codePhraseQuantity per assemblyTechnical document
DFLRREFER TO T.O. 35-1-250T.O. 35-1-25
DFLRREFER TO P0089899590P008989959

Service data

Navy

COG
7E
SMIC
HB
IRRC
00
SMCC
9

Air Force

Budget
M
PVC
X
ERRC
U

Freight

ACTY CD
TG
NMFC
128000
NMFC sub
X
Uniform freight class
64870
Less than truckload
M
Less than carload
P
Water commodity code
743
Type of cargo code
Z
Special handling code
9
Air dimension code
A
Air commodity code
HQ
NMF description
PUMPS PWR NOI/WORKING HEADS/PARTS

Packaging

Unit and preservation

PICA SICAPKG catUnpackaged weightUnpackaged widthUnpackaged lengthUnpackaged heightUnit of issueTOSIntermediate container qtyMethod of preservationClng dryingPres matWrap matCush dunTHKUnit contPKG data source
P0.00000.0000.0000.000EA000
No intermediate container quantity specified (000)
671
Any suitable process that is not injurious to the item.
ZZ
Special requirement – See specific instructions or drawings provided
ZZ
Special requirements – see specific instructions or drawings provided
ZZ
Special requirements.
Z
Special requirements – See specific instructions or drawings provided
ZZ
Special requirement – See specific instructions or drawings provided.
P
SZZZ00.00000.0000.0000.000EAB000
No intermediate container quantity specified (000)
ZZ
Special requirements apply that are not represented by the code symbols; details are provided with the acquisition...
1
Any suitable process that is not injurious to the item.
00
No requirement
ZZ
Special requirements – see specific instructions or drawings provided
ZZ
Special requirements.
Z
Special requirements – See specific instructions or drawings provided
ZZ
Special requirement – See specific instructions or drawings provided.
A

Unit pack

PICA SICASPC MKGInter contUCLLvl ALvl bLvl cUnit pack weightUP SZ MAXBUP SZ MAXLUP SZ MAXHUnit pack cubeOPISupplemental instructions
PZZ
Special requirements
00
No requirement.
A
Unit container provides level A packing protection.
672.000034.0000050.0000032.5000031.9730A
Packaging is in accordance with a procedural specification or an SPI.
S00
No special marking
00
No requirement.
O
Unit container is not an acceptable shipping container.
E
Packing shall be accomplished to meet the performance test requirements of ASTM D4169, Distribution Cycle 18,...
Q
Packing shall be accomplished in accordance with table C-II for the packing level specified.
Q0.000035.0000051.0000034.0000035.1220A
Packaging is in accordance with a procedural specification or an SPI.
ZZ = PACKAGE PER MIL-P-16789 REQUIREMENTS

Packaging instructions

PICA SICASPI noSPI revSPI date
PF010612896D96116
S00000

Full packaging code breakdown

Related items

Standardization

Item standardization code
2
Orig stdzn dec
AX
Dt stdzn dec
01-DEC-1974
NIIN status code
0

Request a quote

Your request goes to A-DEFENSE, a US Defense supplier in Texas, who will reply by email.